An ideal inhalable aerosol sampler for occupational exposure monitoring would have a sampling efficiency that perfectly matches the inhalable particulate matter (IPM) criterion. Two common aerosol samplers in use worldwide are the closed-face cassette (CFC) and the Institute of Occupational Medicine (IOM) sampler. However, the CFC is known to under-sample, with near zero sampling efficiency for particles >30 µm, whereas the IOM, considered by many to be the "gold standard" in inhalable samplers, has been shown to over-sample particles >60 µm. A new sampler in development incorporates characteristics of both the CFC and the IOM. Like the CFC, it would be disposable, have a simple design, and is intended to be oriented at a 45° downward angle. Like the IOM, the new sampler has a 15-mm inlet diameter and incorporates a 25-mm filter cassette with a protruding lip. The IOM is oriented at 0° to the horizontal, so it is hypothesized that orienting the new sampler at ∼45° downward angle will reduce oversampling of larger particles. In comparison, the CFC's inlet diameter is 4 mm; increasing the size of the inlet should allow the new sampler to have an increased efficiency relative to the CFC for all particles. A unique characteristic of the new sampler is the incorporation of a one-piece capsule-style filter that mimics the IOM's cassette but is made of disposable material. Seven different sizes of alumina particles (mean aerodynamic diameters from 4.9-62.4 µm) were tested (total = 124 samples collected). For each test, six samplers were placed on a manikin located inside a wind tunnel operated at 0.2 m/sec. Results indicated that the new sampler improved on the CFC for smaller particles, providing a larger range for which it matches the IPM criterion, up to 44.3 µm. However, the efficiency was significantly lower in comparison to the IPM criterion for particle sizes above 60 µm. Overall, the new sampler showed promise, but additional modifications may help improve sampling efficiency for larger particles.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459624.2019.1632463DOI Listing

Publication Analysis

Top Keywords

sampling efficiency
12
ipm criterion
12
sampler
10
inhalable aerosol
8
iom sampler
8
µm sampler
8
downward angle
8
inlet diameter
8
larger particles
8
particles
7

Similar Publications

Evaluation of an enhanced ResNet-18 classification model for rapid On-site diagnosis in respiratory cytology.

BMC Cancer

January 2025

Department of Pathology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.

Objective: Rapid on-site evaluation (ROSE) of respiratory cytology specimens is a critical technique for accurate and timely diagnosis of lung cancer. However, in China, limited familiarity with the Diff-Quik staining method and a shortage of trained cytopathologists hamper utilization of ROSE. Therefore, developing an improved deep learning model to assist clinicians in promptly and accurately evaluating Diff-Quik stained cytology samples during ROSE has important clinical value.

View Article and Find Full Text PDF

Genome-wide development of simple sequence repeat (SSR) markers at 2-Mb intervals in lotus (Nelumbo Adans.).

BMC Genomics

January 2025

Shanghai Key Laboratory of Plant Functional Genomics and Resources, Shanghai Chenshan Botanical Garden, No. 3888 Chenhua Road, Songjiang District, Shanghai, 201602, China.

Background: Despite the rapid advancement of high-throughput sequencing, simple sequence repeats (SSRs) remain indispensable molecular markers for various applied and research tasks owing to their cost-effectiveness and ease of use. However, existing SSR markers cannot meet the growing demand for research on lotus (Nelumbo Adans.) given their scarcity and weak connections to the lotus genome.

View Article and Find Full Text PDF

Purpose: The aim of the present study was to establish a SYBR Green-based real-time PCR assay for detection of the Nc5 segment from the Neospora caninum genome.

Methods: The oligonucleotides sequences targeting the Nc5 gene previously reported and designed in-house were validated. Two Primer sets were evaluated and tested in four different combinations.

View Article and Find Full Text PDF

Flow prediction in sound-based uroflowmetry.

Sci Rep

January 2025

Department of Signal Theory and Communications, Universidad de Valladolid, 47002, Valladolid, Spain.

Sound-based uroflowmetry (SU) offers a non-invasive alternative to traditional uroflowmetry (UF) for evaluating lower urinary tract dysfunctions, enabling home-based testing and reducing the need for clinic visits. This study compares SU and UF in estimating urine flow rate and voided volume in 50 male volunteers (aged 18-60), with UF results from a Minze uroflowmeter as the reference standard. Audio signals recorded during voiding were segmented and machine learning algorithms (gradient boosting, random forest, and support vector machine) estimated flow parameters from three devices: Ultramic384k, Mi A1 smartphone, and Oppo smartwatch.

View Article and Find Full Text PDF

Bovine mastitis is the most widespread disease that causes financial loss in the dairy industry. Staphylococcus aureus is a well-researched multidrug-resistant opportunistic bacterium that is frequently linked to subclinical mastitis and causes significant economic losses. A further problem in the management of S.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!