Adherence and inhaler technique are often suboptimal in asthma and chronic obstructive pulmonary disease (COPD). New inhalers have been developed to improve these determinants of treatment effectiveness. We assessed treatment adherence, satisfaction, and ease of use of DuoResp Spiromax among SPRINT study participants. The Phase IV SPRINT study was conducted in 10 European countries. Asthma and COPD patients were receiving a fixed-dose combination of inhaled corticosteroid (ICS) and long-acting β-agonist (LABA), delivered via various inhalers including DuoResp Spiromax. DuoResp Spiromax users self-assessed adherence using the 8-item Morisky Medication Adherence Scale (MMAS-8), and ease of use and satisfaction using 10-point scales, during a single physician's office visit. Of 1661 (asthma: = 1101; COPD: = 560) SPRINT study participants, 342 (asthma: 235; COPD: 107) received DuoResp Spiromax prior to inclusion. Overall, 72.5% of DuoResp Spiromax users reported medium or high adherence (MMAS-8 score ≥6). Mean (standard deviation [SD]) satisfaction score for DuoResp Spiromax was 8.9 (1.6). Almost all (98.8%) DuoResp Spiromax users were at least satisfied with their inhaler; 85.4% were very satisfied. Mean (SD) ease of use score for DuoResp Spiromax was 9.1 (1.3). Asthma and COPD patients using DuoResp Spiromax reported moderate-to-high medication adherence, were very satisfied with their inhaler and found it easy to use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02770903.2019.1634097 | DOI Listing |
Eur J Pharm Sci
July 2023
Emmace Consulting AB, Lund, Sweden.
The device or the formulation? Which one governs drug dispersibility from the inhaler? To address this question, three budesonide-containing reservoir DPIs: Novopulmon Novolizer®, Giona Easyhaler® and DuoResp Spiromax®, were analyzed using the Next Generation Impactor, NGI. Thereafter, the devices were carefully opened, emptied, and formulations were switched between devices. Finally, three 'prototype' formulations with carriers of different particle size were produced and tested in the Novolizer and Easyhaler devices.
View Article and Find Full Text PDFJ Asthma
April 2022
Teva Santé, Courbevoie, France.
In asthma, treatment effectiveness is strongly influenced by the quality of inhaler use. New devices such as Spiromax® have been specifically developed to improve ease of use. It is crucial to determine whether switching to such a device improves inhaler technique and clinical outcomes, and to identify factors associated with handling errors.
View Article and Find Full Text PDFEur Clin Respir J
October 2020
Department of Respiratory Medicine, Hospital de la Santa Creu i Sant Pau. Institut d'Investigació Biomédica Sant Pau (IIB Sant Pau), Universitat Autónoma de Barcelona, Department of Medicine, Barcelona, Spain.
While poor inhaler technique in asthma and chronic obstructive pulmonary disease (COPD) can compromise the effectiveness of inhaled medications, identifying and quantifying these errors may suggest ways to improve inhalation technique and patient outcomes. The objective of this international, multicentre care improvement programme was to investigate errors in inhaler use (handling errors and inhalation errors) made by patients in handling two dry powder inhalers; DuoResp® Spiromax® and Symbicort® Turbuhaler®. Patients with asthma or COPD aged between 18 and 80 years attending the allergology/pneumology departments of 14 hospitals in Spain and Portugal were included.
View Article and Find Full Text PDFEur J Pharm Sci
November 2019
Department of Pharmacy and Pharmaceutical Sciences, School of Applied Sciences, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, United Kingdom. Electronic address:
Dry powder inhalers (DPIs) are passive devices used to administer inhaled medication for the management of asthma and chronic obstructive pulmonary disease (COPD). DPIs require patients to generate a sufficient internal turbulent airflow force during each inhalation to deaggregate the powdered drug formulation into an emitted dose containing particles with the greatest likelihood of lung deposition. This internal force is generated by the interaction between the user's inhalation flow and the resistance of the DPI.
View Article and Find Full Text PDFJ Asthma
October 2020
Department of Respiratory Medicine, Bispebjerg University Hospital, Copenhagen University, Copenhagen, Denmark.
Adherence and inhaler technique are often suboptimal in asthma and chronic obstructive pulmonary disease (COPD). New inhalers have been developed to improve these determinants of treatment effectiveness. We assessed treatment adherence, satisfaction, and ease of use of DuoResp Spiromax among SPRINT study participants.