Objectives: The Gekkou-drill® is an industrial drill that is highly efficient due to reduced cutting resistance resulting from its characteristic drill point shape. In this experiment, we compared the degree of thermal damage to bone tissue caused by conventional medical drills and these same drills with Gekkou modifications.
Methods: Holes were created in the tibias of living pigs using two different 3.2-mm diameter drills and their modified versions. Regarding the drilling parameters, the thrust force was 10 N and the drilling speeds were 800 revolutions per minute (rpm) and 1500 rpm. We compared the original and modified drills in terms of the bone temperature around the drill bit and the total time necessary to create each hole, the latter calculated using imaging data captured during drilling. In histopathological examination, the percentages of empty lacunae in osteocytes of the cortical bone beneath the periosteum were evaluated at 400 × magnification with an optical microscope.
Results: Compared to the original drills, the modified drills required significantly less time to create each hole and caused a significantly lower temperature rise during bone drilling. With the modified drills, the percentages of empty lacunae around the drilling holes were about 1/2-1/3 of those with the original drills, and were significantly lower for both drilling speeds.
Conclusions: Gekkou-modified medical drills shortened drilling times despite low thrust force, and histopathological assessment demonstrated a significant reduction in osteocyte damage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00402-019-03239-y | DOI Listing |
Appl Environ Microbiol
January 2025
Clinical Infection Department, Chelsea and Westminster Hospital NHS Foundation Trust, London, United Kingdom.
Unlabelled: Remote polar regions offer unique opportunities and significant challenges for antimicrobial resistance research in a near-pristine environment. While core microbiology techniques continue to have an important role in supporting environmental research, the severe cold climate presents considerable challenges to laboratory research. We explore adaptations required for core bacteriology investigations in polar regions on an unsupported remote expedition c.
View Article and Find Full Text PDFLoading with non-metal cocatalysts to regulate interfacial charge transfer and separation has become a prominent focus in current research. In this study, g-CN/CNT composites loaded with non-metallic cocatalysts were prepared through pyrolysis using urea and CNTs. Various characterization techniques, including transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), ultraviolet-visible diffuse reflectance spectroscopy (UV-vis DRS), photoelectrochemical (PEC) analysis, fluorescence lifetime spectroscopy (TRPL), electron paramagnetic resonance spectroscopy (ESR), and photoluminescence (PL) spectroscopy, were employed to analyze the sample's microstructure, phase composition, elemental chemical states, and photoelectronic properties.
View Article and Find Full Text PDFSensors (Basel)
January 2025
State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum, Beijing 102249, China.
Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.
View Article and Find Full Text PDFCarbohydr Polym
March 2025
School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, China. Electronic address:
Xanthan gum (XG), recognized for its environmentally friendly properties and versatile capabilities, has been studied for drilling fluid applications. However, its limited solubility and thermal stability restricts its broader use. In this study, a modified XG derivative, XG-g-KH570 modified SiO, was synthesized by grafting XG with KH570-modified nano-SiO.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopedics and Rehabilitation, University of Vermont, Burlington, Vermont, USA.
Background: A lateral extra-articular tenodesis (LET) is increasingly being utilized to augment an anterior cruciate ligament reconstruction because it has been shown to reduce the risk of postreconstruction graft failure or recurrent rotatory instability. Various femoral fixation techniques are available, including the use of an interference screw, staple, or suture anchor.
Purpose: To determine and compare the biomechanical properties of an LET graft when using an interference screw, staple, or suture anchor for the femoral fixation for a modified Lemaire LET.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!