Evaluation of Isobornyl Acrylate Content in Medical Devices for Diabetes Treatment.

Diabetes Technol Ther

Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilian University, Munich, Germany.

Published: October 2019

Along with increased usage of continuous glucose monitors, flash glucose monitors, and patch pumps by patients with diabetes, the frequency of skin reactions has also increased. Skin irritation and itching can be annoying to users. However, more serious contact allergies to one or more components of the adhesives or plastic material of the housing of the devices can become lifelong. Redness and itchiness are so strong that patients can no longer use a particular system. In August 2017, a major culprit allergen, isobornyl acrylate (IBOA), was identified for these more serious reactions. Our objective was to evaluate IBOA content in different medical products. The plastic material used for the housing of the Freestyle Libre ( = 3), Dexcom G6 ( = 3), and Enlite ( = 4) was analyzed for IBOA content by gas chromatography-mass spectrometry. Adhesives of the different systems were also analyzed. IBOA was found in the housings of Freestyle Libre and Enlite sensor, but not in the Dexcom G6. Patients with an IBOA allergy should consider switching to a medical product without IBOA. Furthermore, removal of IBOA from devices that contact the skin is encouraged.

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2019.0163DOI Listing

Publication Analysis

Top Keywords

isobornyl acrylate
8
content medical
8
glucose monitors
8
plastic material
8
material housing
8
iboa content
8
freestyle libre
8
analyzed iboa
8
iboa
7
evaluation isobornyl
4

Similar Publications

The photopolymerization-induced microphase separation (photo-PIMS) process involving a reactive polymer block was implemented to fabricate nanostructured quasi-solid polymer electrolytes (QSPEs) for use in lithium metal batteries (LMBs). This innovative one-pot fabrication enhances interfacial properties in LMBs by enabling nanostructuring of QSPE directly onto the electrodes. This process also allows for customization of QSPE structural dimensions by tweaking the architecture and molar mass of poly[(oligo ethylene glycol) methyl ether methacrylate--styrene] (P(OEGMA--S)) macromolecular chain transfer agent.

View Article and Find Full Text PDF

Hydrophobic materials have been fabricated by DLP vat photopolymerization of isobornyl acrylate-based resins with chemical modification and/or surface geometry engineering. Fluorinated and polydimethylsiloxane (PDMS)-based acrylic monomers are used for chemical modification and are incorporated into the printed materials. The water wettability was significantly reduced and plateaued with as low as 5% (w/w) of the auxillary hydrophobic monomer.

View Article and Find Full Text PDF

Exploiting Seeded RAFT Polymerization for the Preparation of Graft Copolymer Nanoparticles.

Macromol Rapid Commun

November 2024

Department of Polymeric Materials and Engineering, School of Materials and Energy, Guangdong University of Technology, Guangzhou, 510006, China.

Although seeded reversible addition-fragmentation chain transfer (RAFT) polymerization is explored as a unique method for the preparation of block copolymer nanoparticles with diverse structures, the preparation of nonlinear polymer nanoparticles by seeded RAFT polymerization is rarely reported. Herein, linear block copolymer nanoparticles are first prepared by RAFT dispersion copolymerization of benzyl methacrylate (BzMA) and 2-(2-(n-butyltrithiocarbonate)propionate)ethyl methacrylate (BTPEMA) with different [BzMA]/[BTPEMA] ratios, and employed as seeds for seeded RAFT polymerization of isobornyl acrylate (IBOA) to prepare graft copolymer nanoparticles with different numbers of PIBOA side chains. Comparing with linear triblock copolymers with the same chemical composition, the graft copolymers can promote the formation of higher-order morphologies (e.

View Article and Find Full Text PDF

During the past 8 years, a large number of reports have appeared on allergic contact dermatitis to glucose sensors and insulin pumps in paediatric and adult patients with type 1 diabetes mellitus. Isobornyl acrylate in one particular sensor sensitised many hundreds of (published) individuals, and many other allergens were discovered in a large number of sensors and pumps. Diagnostic procedures with patch tests proved very complicated, as manufacturers showed a serious lack of cooperation with dermatologists in providing information on the ingredients of their products and samples for patch testing.

View Article and Find Full Text PDF

During the past 8 years, a large number of reports have appeared on allergic contact dermatitis to glucose sensors and insulin pumps in paediatric and adult patients with type 1 diabetes mellitus. Isobornyl acrylate in one particular sensor sensitised many hundreds of (published) individuals, and many other allergens were discovered in a large number of sensors and pumps. Diagnostic procedures with patch tests proved very complicated, as manufacturers showed a serious lack of cooperation with dermatologists in providing information on the ingredients of their products and samples for patch testing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!