Aims: The sex-related differences in the clinical outcomes of rhythm and safety after catheter ablation remain unclear. The purpose of this study was to compare the clinical outcomes of catheter ablation for atrial fibrillation (AF) in women and men.

Methods And Results: The Medline and EMBASE databases were searched for published articles up to December 2018. Studies that met our predefined inclusion criteria were included. The primary endpoints were freedom from AF/atrial tachycardia (AT) recurrence, stroke/transient ischaemic attack (TIA), and all-cause mortality. After literature search and detailed assessment, 19 observational studies (151 370 patients; 34% women) were identified. Our analyses showed that the rate of freedom from AF/AT recurrence was lower in women than men at the 2.4-year follow-up [odds ratio (OR): 0.75, 95% confidence interval (CI) 0.69-0.81; P < 0.0001]. Moreover, women had an increased risk of stroke/TIA (OR: 1.42, 95% CI 1.21-1.67; P < 0.0001) and all-cause mortality (OR: 1.53, 95% CI 1.02-2.28; P = 0.04). Nevertheless, for the endpoint of all-cause mortality, there was no significant difference between the two genders in the subgroup of prospective studies (OR: 1.19, 95% CI 0.69-2.05; P = 0.53). Additionally, women were more likely to experience major complications compared with men (pericardial effusion/tamponade, major bleeding requiring transfusion, and pacemaker implantation).

Conclusions: Women who underwent catheter ablation of AF might experience lower efficacy and a higher risk of stroke/TIA and major complications than men. The reasons for these sex-related differences need to be further studied.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euz179DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
sex-related differences
8
ablation atrial
8
atrial fibrillation
8
clinical outcomes
8
differences catheter
4
fibrillation systematic
4
systematic review
4
review meta-analysis
4
meta-analysis aims
4

Similar Publications

Background: Postprocedural pericarditis (PP) can occur in up to 29.4% of patients undergoing epicardial catheter ablation of ventricular tachycardia (VT). Despite several proposed strategies to mitigate this adverse outcome, rates of PP and pericarditic pain remain high.

View Article and Find Full Text PDF

Postablation Arrhythmogenic Channels Predict Atrial Fibrillation Recurrence: Iatrogenic Substrate Revisited.

JACC Clin Electrophysiol

January 2025

Department of Cardiology, Hospital Clínic Cardiovascular Institute (ICCV), Universitat de Barcelona, Barcelona, Catalonia, Spain; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Catalonia, Spain. Electronic address:

View Article and Find Full Text PDF

Atrial Fibrillation and Flutter in a Contemporary Cohort of Patients With Myotonic Muscular Dystrophy.

JACC Clin Electrophysiol

January 2025

Section of Cardiac Electrophysiology, Cardiovascular Medicine Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Background: Literature on the prevalence and management of atrial arrhythmias in patients with myotonic muscular dystrophy type 1 (MMD1) or myotonic muscular dystrophy type 2 (MMD2) is limited.

Objectives: This study sought to describe incidence, prevalence, and predictors of atrial fibrillation (AF) and atrial flutter (AFL) in a contemporary cohort of patients with myotonic muscular dystrophy (MMD).

Methods: Associations between patient factors and incident AF/AFL were analyzed in patients with MMD referred for routine electrophysiology evaluation between January 2013 and September 2023.

View Article and Find Full Text PDF

Whole-Heart Histological and CMR Validation of Electroanatomic Mapping by Multielectrode Catheters in an Ovine Model.

JACC Clin Electrophysiol

January 2025

Department of Cardiology, Westmead Hospital, Sydney, New South Wales, Australia; Westmead Applied Research Centre, University of Sydney, Sydney, New South Wales, Australia. Electronic address:

Background: Accurate electroanatomic mapping is critical for identifying scar and the long-term success of ventricular tachycardia ablation.

Objectives: This study sought to determine the accuracy of multielectrode mapping (MEM) catheters to identify scar on cardiac magnetic resonance (CMR) and histopathology.

Methods: In an ovine model of myocardial infarction, we examined the effect of electrode size, spacing, and mapping rhythm on scar identification compared to CMR and histopathology using 5 multielectrode mapping catheters.

View Article and Find Full Text PDF

Restitution Threshold Index: Looking Beyond the Mean Heart Rate.

JACC Clin Electrophysiol

January 2025

Division of Cardiac Electrophysiology, Virginia Commonwealth University, Richmond, Virginia, USA; Division of Cardiac Electrophysiology, Central Virginia Veterans Affairs Health System, Richmond, Virginia, USA. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!