A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Theoretical investigation into the influence of molar ratio on mixture system: α, γ, δ-HMX molecules coexisting with β-HMX crystal. | LitMetric

Molecular dynamics (MD) simulation was conducted to research the effect of molar ratios for α/β-HMX, γ/β-HMX, and δ/β-HMX(octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) mixture systems on thermal stability, sensitivity, and mechanical properties of explosives, and the computing models were established by Materials Studio (MS). The binding energies, the maximum trigger bond length (L), cohesive energy density as well as mechanical properties of the mixture systems and the pure β-HMX crystal were obtained and contrasted. The results demonstrate that the molar ratios have great influence on the binding capacity of molecules between α, γ, δ-HMX, and β-HMX in the mixture systems. The binding energies decrease with the increase of molecular molar ratio and have the maximum values at the 1:1 M ratio. The maximum trigger bond length does not change apparently after mixing, while the cohesive energy density (CED) increases as the molar ratio increases but are all smaller than the pure β-HMX crystal, demonstrating that the sensitivity of the mixture systems increases. The mechanical properties decrease after mixture, which illustrates that the mechanical properties of the pure crystal are superior to the mixture systems.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00894-019-4097-1DOI Listing

Publication Analysis

Top Keywords

mixture systems
20
mechanical properties
16
molar ratio
12
β-hmx crystal
12
molar ratios
8
binding energies
8
maximum trigger
8
trigger bond
8
bond length
8
cohesive energy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!