Background: Bone defects can be filled with autografts, allografts and artificial bone-materials. The aim of this study was to evaluate whether the digitization of known defect models with a navigation system is a reliable measurement method for estimating the size of a bone defect.

Methods: Six preformed, cylindrical and cone-shaped defects on an artificial hip-bone were digitalized by six different observers. Reference volumes were gathered by measuring the depth of the defects, using an alginate impression material to fill out the defects and calculating the volumes from a CT scan.

Results: One out of the six preformed defects showed a statistically significant difference between the digitalization and the calculation, four showed a significant difference between the digitalization and the mould as well as between the digitalization and the CT calculation.

Conclusions: This technique offers satisfactory results and consistent reproducibility when digitalizing big defects with relatively simple shape. Decreasing size and increasing complexity of the defects leads to more imprecise measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2019.103336DOI Listing

Publication Analysis

Top Keywords

defects
8
bone defects
8
difference digitalization
8
measuring bone
4
defects acetabular
4
acetabular revision
4
revision surgery
4
surgery choosing
4
choosing appropriate
4
appropriate reconstruction
4

Similar Publications

Introduction: The nasoseptal flap (NSF) has become a widely favoured choice for reconstructing skull base defects following the endoscopic endonasal approach (EEA). However, the exposed septal cartilage and bone at the donor site often require an extended duration for secondary healing. This study investigated whether the free middle turbinate (MT) mucosa grafting at the septal donor site could mitigate post-operative nasal morbidity.

View Article and Find Full Text PDF

Distal femoral replacement (DFR) with megaprostheses is a salvage revision total knee arthroplasty (rTKA) procedure indicated in cases with massive bone defects in the distal femur. As long as these implants achieve fixation only in the diaphysis, the high aseptic loosening rate reported in some series is probably related to a lack of rotational stability. Two patients with extensive distal femoral bone defects with preservation of the metaphyseal-diaphyseal junction underwent rTKA.

View Article and Find Full Text PDF

Reimbursement policies of Swiss health insurances for the surgical treatment of symptomatic breast hypertrophy: a retrospective cohort study.

Swiss Med Wkly

January 2025

Department of Plastic, Reconstructive and Aesthetic Surgery, Ospedale Regionale di Lugano, Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland.

Background: Patients with symptomatic breast hypertrophy typically suffer from chronic back pain, recurrent skin irritation at the inframammary fold and/or low self-esteem resulting in impaired quality of life. Reduction mammaplasty has been shown to effectively treat symptomatic breast hypertrophy with high patient satisfaction. Despite the obvious benefits, reimbursement requests for reduction mammaplasty are initially often refused by the patient's health insurance company, thereby frequently resulting in additional examinations and eventually extra expenses.

View Article and Find Full Text PDF

Background: Many studies indicate that high and multiple doses of anabolic-androgenic steroids (AAS) for athletic enhancement can result in serious and irreversible adverse effects. A study that includes laboratory blood testing to evaluate the direct effects of AAS agents among users has not been previously undertaken. The purpose of this study was to investigate the adverse effects of the use of AAS by athletes and to determine whether AAS use leads to changes in certain blood parameters.

View Article and Find Full Text PDF

Intramural pregnancy (IMP) is an extremely rare form of ectopic pregnancy (EP), typically associated with previous uterine trauma, adenomyosis, or assisted reproductive technology (ART), such as embryo transfer (ET). Despite its potentially life-threatening nature, the absence of definitive preoperative diagnostic criteria for IMP complicates its early detection and management, especially in patients without known risk factors. Additionally, management becomes more challenging when there is an elevated risk of hemorrhage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!