Radiochromic films have been widely studied for clinical dosimetry in conventional external beam radiation therapy. With an increase in practice of proton therapy, such films are being conveniently used; however, their spectroscopic characterization for this modality is lacking. This work investigated the response of the EBT3 radiochromic films irradiated in a Mevion S250 clinical proton beam. Dose, dose rate, inter-batch, sensitivity, and linear energy transfer (LET) dependencies of the films were studied. Pieces of the radiochromic films from different batches were irradiated using a spread-out Bragg peak (SOBP) proton beam at dose levels between 0.1-15 Gy. Absorption spectra were measured in the wavelength range of 400-800 nm with 2.5 nm resolution. For comparison, the optical density of the films was measured using a flatbed scanner. The net absorbance spectra showed two characteristic absorption bands centered at 636 nm and 585 nm. However, a saturation effect, manifested as broadening/splitting appearance, was observed in the 636 nm band for doses beyond a certain batch-dependent level ~4-10 Gy, in the three different film batches studied. The differences in the spectral shape led to dose-response curves with variable sensitivity. In general a high spectral sensitivity was observed in 0.1-6 Gy range for the three film batches. For a given dose, no significant change in the spectra was observed with change in the dose rate. No significant dependency on the LET was observed for the EBT3 films irradiated with proton beams with dose-averaged LETs ranging from 1.14-6.50 keV µm studied in this work. However, at a given dose, ~5% lower spectral response was observed in the films irradiated with protons compared to their counterparts irradiated with photon beams.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab23cdDOI Listing

Publication Analysis

Top Keywords

radiochromic films
16
films irradiated
16
films
9
clinical proton
8
proton beams
8
films studied
8
proton beam
8
beam dose
8
dose rate
8
three film
8

Similar Publications

Purpose: In radiotherapy treatment planning systems, modelling of superficial dose may be aided by a body contour that is, by default, placed at the outermost air-tissue interface. Here we investigate the accuracy of superficial dose calculated using either the default body contour (DBC) or an extended body contour (EBC) compared to radiochromic film measurements made on a slab phantom and an anthropomorphic phantom.

Methods: Depth dose curves in the superficial region of the slab phantom were measured using stacked radiochromic films and irradiated using static beams delivered from varying incident angles.

View Article and Find Full Text PDF

This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.

View Article and Find Full Text PDF

This study analyzed the spectral response of EBT3, EBT4, and EBT-XD radiochromic films using absorption spectroscopy. The primary focus was on characterizing the evolution of spectral signatures across a range of absorbed doses, thereby elucidating the unique dose-dependent response profiles of each film type. Ten samples of each film type were subjected to open field irradiation within their designated dose ranges (1-20 Gy for EBT3 and EBT4, 1-50 Gy for EBT-XD).

View Article and Find Full Text PDF

The sensitivity of radiochromic films to UV-blue light is increasingly considered for light dosimetry purposes, owing to their bidimensional detection capabilities and ease of use. While film response to radiation intensity has been widely investigated by commercial scanners, spatial resolution studies remain scarce, especially for small field-of-view applications. These are of growing interest due to the antimicrobial or photo-bio-stimulating effects of UV-blue light sources in in vitro, ex vivo and in vivo models, where precise knowledge of irradiation conditions with adequate spatial resolution is crucial.

View Article and Find Full Text PDF

This work investigates the low photon radiation dose (≤50 mSv) response of commercially available radiochromic films as a potential field dosimeter that could be used by the Canadian Armed Forces to complement their existing personal radiation dosimeters. The films were exposed to various photon energies from x-ray devices and radioisotopes (cesium-137, cobalt-60, and americium-241), and their radiation signal was read using three methods: net optical density, UV/visible spectroscopy, and Fourier transform infrared spectroscopy. A complimentary film dosimeter for field usage should, for military use, display a visual color change and detect doses ≤50 mSv.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!