Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Compound-specific isotope analysis (CSIA) is a powerful tool to understand the fate of organic contaminants. Using CSIA, the isotope ratios of multiple elements (δC, δH, δCl, δN) can be measured for a compound. A dual-isotope plot of the changes in isotope ratios between two elements produces a slope, lambda (Λ), which can be instrumental for practitioners to identify transformation mechanisms. However, practices to calculate and report Λ and related uncertainty are not universal, leading to the potential for misinterpretations. Here, the most common methods are re-evaluated to provide the basis for a more accurate best-practice representation of Λ and its uncertainty. The popular regression technique, ordinary linear regression, can introduce mathematical bias. The York method, which incorporates error in both variables, better adapts to the wide set of data conditions observed for dual-isotope data. Importantly, the existing technique of distinguishing between Λs using the 95% confidence interval alone produces inconsistent results, whereas statistical hypothesis testing provides a more robust method to differentiate Λs. The propensity for Λ to overlap for a variety of conditions and mechanisms highlights the requirement for statistical justification when comparing data sets. Findings from this study emphasize the importance of this evaluation of best practice and provide recommendations for standardizing, calculating, and interpreting dual-isotope data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.9b01756 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!