Dual-Energy Computed Tomography to Assess Intra- and Inter-Patient Tissue Variability for Proton Treatment Planning of Patients With Brain Tumor.

Int J Radiat Oncol Biol Phys

OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology-OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), Partner Site Dresden, Germany.

Published: November 2019

Purpose: Range prediction in particle therapy is associated with an uncertainty originating from calculating the stopping-power ratio (SPR) based on x-ray computed tomography (CT). Here, we assessed the intra- and inter-patient variability of tissue properties in patients with primary brain tumor using dual-energy CT (DECT) and quantified its influence on current SPR prediction.

Methods And Materials: For 102 patients' DECT scans, SPR distributions were derived from a patient-specific DECT-based approach (DirectSPR). The impact of soft tissue diversity and age-related variations in bone composition on SPR were assessed. Tissue-specific and global deviations between this method and the state-of-the-art CT-number-to-SPR conversion applying a Hounsfield look-up table (HLUT) were quantified. To isolate systematic deviations between the two, the HLUT was also optimized using DECT information.

Results: An intra-patient ± inter-patient soft tissue diversity of 5.6% ± 0.7% in SPR (width of 95% confidence interval) was obtained including imaging- and model-related variations of up to 2.9%. This intra-patient SPR variability is associated with a mean absolute SPR deviation of 1.2% between the patient-specific DirectSPR approach and an optimal HLUT. Between adults and children younger than 6 years, age-related variations in bone composition resulted in a median SPR difference of approximately 5%.

Conclusions: Accurate patient-specific DECT-based stopping-power prediction allows for improved handling of tissue mixtures and can intrinsically incorporate most of the SPR variability arising from tissue mixtures as well as inter-patient and intra-tissue variations. Since the state-of-the-art HLUT-even after cohort-specific optimization-cannot fully consider the broad tissue variability, patient-specific DECT-based stopping-power prediction is advisable in particle therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2019.06.2529DOI Listing

Publication Analysis

Top Keywords

patient-specific dect-based
12
computed tomography
8
intra- inter-patient
8
tissue variability
8
brain tumor
8
particle therapy
8
spr
8
soft tissue
8
tissue diversity
8
age-related variations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!