Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare the objective and subjective image quality indicators and radiation doses of computed tomography (CT) venography performed using model-based iterative reconstruction (MBIR) at 80 kVp and adaptive statistical iterative reconstruction (ASIR)-V at 70 kVp.
Materials And Methods: Eighty-three patients who had undergone CT venography of the lower extremities with MBIR at 80 kVp (Group A; 21 men and 20 women; mean age, 55.5 years) or ASIR-V at 70 kVp (Group B; 18 men and 24 women; mean age, 57.3 years) were enrolled. Two radiologists retrospectively evaluated the objective (vascular enhancement, image noise, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR]) and subjective (quantum mottle, delineation of contour, venous enhancement) image quality indicators at the inferior vena cava and femoral and popliteal veins. Clinical information, radiation dose, reconstruction time, and objective and subjective image quality indicators were compared between groups A and B.
Results: Vascular enhancement, SNR, and CNR were significantly greater in Group B than in Group A ( ≤ 0.015). Image noise was significantly lower in Group B ( ≤ 0.021), and all subjective image quality indicators, except for delineation of vein contours, were significantly better in Group B ( ≤ 0.021). Mean reconstruction time was significantly shorter in Group B than in Group A (1 min 43 s vs. 131 min 1 s; < 0.001). Clinical information and radiation dose were not significantly different between the two groups.
Conclusion: CT venography using ASIR-V at 70 kVp was better than MBIR at 80 kVp in terms of image quality and reconstruction time at similar radiation doses.