Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Though the use of small bolus doses of vasopressors, termed "push dose pressors," has become common in emergency medicine, data examining this practice are scant. Push dose pressors frequently involve bedside dilution, which may result in errors and adverse events. The objective of this study was to assess for instances of human error and adverse hemodynamic events during push dose pressor use in the emergency department.
Methods: This was a structured chart and video review of all patients age ≥ 16 years undergoing resuscitation and receiving push dose pressors from a single center from January 2010 to November 2017. Push dose pressors were defined as intended intravenous boluses of phenylephrine (any dose) or epinephrine (≤ 100 mcg).
Results: A total of 249 patients were analyzed. Median age was 60 years (range, 16-97), 58% were male, 49% survived to discharge. Median initial epinephrine dose was 20 mcg (n = 139, IQR 10-100, range 1-100); median phenylephrine dose was 100 mcg (n = 110, IQR 100-100, range 25-10,000). Adverse hemodynamic events occurred in 98 patients (39%); 30 in the phenylephrine group (27%; 95% CI, 19-36%), and 68 in the epinephrine group (50%; 95% CI, 41-58%). Human errors were observed in 47 patients (19%), including 7 patients (3%) experiencing dosing errors (all overdoses; range, 2.5- to 100-fold) and 43 patients (17%) with a documentation error. Only one dosing error occurred when a pharmacist was present.
Conclusions: Human errors and adverse hemodynamic events were common with the use of push dose pressors in the emergency department. Adverse hemodynamic events were more common than in previous studies. Future research should determine if push dose pressors improve outcomes and if so, how to safely implement them into practice.