A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A long-term mechanical cavopulmonary support device for patients with Fontan circulation. | LitMetric

In patients with a single ventricle, failure of the cardiovascular system may be prevented by substituting the missing sub-pulmonary ventricle with a pump. The aim of this study was to design and evaluate a device for long-term cavopulmonary support. A radial pump with two inlets and two outlets, a single impeller, mechanical bearings, and dual motor configuration was developed. Motor and fluid dynamic components were designed and simulated using computational methods including thermal effects. Hydraulic properties were determined in-vitro with 3D-printed prototypes. The pump design was virtually implanted in an MRI-derived total cavopulmonary connection (TCPC). Computational fluid dynamics (CFD) showed flow fields without regions of flow stagnation (velocity < 0.1 m/s) and only minor recirculations within the pump between 2-10 L/min against pressure heads of 0-50 mmHg at 2500-5000 rpm. The computed maximum temperature increase of blood due to motor heat was 1.3 K. Virtual implantation studies showed that the pump would introduce an additional volume of approximately 4 mL. Experimentally determined hydraulic performance results agreed well with CFD (deviation of <1.3 mmHg) and indicated pressure-sensitive characteristics (∼-2.6 mmHg/(L/min)) while balancing the two inlet pressures (∆P < 2.5 mmHg) under imbalanced inflow conditions. Through in-silico and in-vitro investigations, we demonstrated a promising pump design, which fulfills the basic requirements for long-term cavopulmonary support.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2019.06.017DOI Listing

Publication Analysis

Top Keywords

cavopulmonary support
8
long-term mechanical
4
mechanical cavopulmonary
4
support device
4
device patients
4
patients fontan
4
fontan circulation
4
circulation patients
4
patients single
4
single ventricle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!