Analysis of excimer laser treatment outcomes and corresponding angle κ in hyperopic astigmatism.

J Cataract Refract Surg

Care Vision Nuremberg, Nuremberg, Germany; Care Vision Hamburg, Hamburg, Germany; University Hamburg, Department of Ophthalmology, Hamburg, Germany.

Published: July 2019

Purpose: To investigate the prevalence of preoperative, intraoperative, and postoperative angle κ in hyperopic eyes and its effect on the refractive outcomes of excimer laser vision correction.

Setting: University Hospital Hamburg and Care Vision Refractive Centers, Germany.

Design: Retrospective multicenter study.

Methods: Hyperopic patients after laser in situ keratomileusis and before retreatment because of hyperopic regression were included. Three treatment groups were defined based on the magnitude of preoperative angle κ defined as low (<0.25 mm), moderate (0.25 to 0.50 mm), or high (>0.50 mm).

Results: The study analyzed 170 hyperopic eyes of 112 patients (mean age 29.8 years ± 10.04 [SD], range 21 to 62 years). The preoperative angle κ was low, moderate, or high in 23, 49, and 98 cases, respectively. In eyes with a preoperative angle κ of 0.25 mm or more, changes in the x-axes and y-axes of angle κ and its magnitude were statistically significant (P < .05) between preoperative and intraoperative measurements. In these eyes, intraoperative angle κ (offset) was statistically significantly smaller (P < .05), and Purkinje images were statistically significantly more caudal (P < .001). Treatment predictability was independent from using preoperative or intraoperative angle κ, and there were no statistically significant differences in efficacy or safety.

Conclusions: A preoperative magnitude of angle κ as high as 0.50 mm or higher was present in more than 50% of regressed hyperopic eyes. Measuring angle κ preoperatively did not reflect its real-time intraoperative magnitude. Using the preoperatively larger angle κ as an intraoperative offset might result in a too nasally centered ablation that causes topographic and optical drawbacks; therefore, centering the ablation based on the intraoperative measured offset is recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2019.01.030DOI Listing

Publication Analysis

Top Keywords

preoperative angle
12
excimer laser
8
angle hyperopic
8
hyperopic eyes
8
angle
6
hyperopic
5
analysis excimer
4
laser treatment
4
treatment outcomes
4
outcomes corresponding
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!