A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Topography Measurements Using High Mass Resolution Time-of-Flight Secondary Ion Mass Spectrometry: Application to Banknotes. | LitMetric

Topography Measurements Using High Mass Resolution Time-of-Flight Secondary Ion Mass Spectrometry: Application to Banknotes.

Anal Chem

Research and Development Department , Lebanese Atomic Energy Commission-CNRS , P.O. Box 11-8281, Beirut 1107 2260 , Lebanon.

Published: July 2019

An unconventional approach using the time-of-flight secondary ion mass spectrometry (TOF-SIMS) technique to determine the height topography at the microscale is detailed in this work with an application to cotton paper banknotes. The study was conducted by determining the effect of all related factors and parameters on the height measurement by taking the simplest model made from two Post-it sheets. For each sample, the difference in the TOF of the same secondary ion coming from two different heights was successfully attributed to the step height of the studied areas' topography, which was measured using classic methods. The measurement was independent of the orientation of the topography with regard to the primary ion beam and the electron beam azimuth. Moreover, the adjustment of the extraction gap with different layers has no effect on such measurements. However, a range of the analyzer acceptance energy values could be considered to achieve the expected outcomes only if the different analyzers' component energies are also changing accordingly. Heights between 20 and 180 μm were successfully measured using this new method. An added benefit to this method over other height measurement methods is the ability to discern areas with different chemical compositions, which eventually may help aid understanding of the sample in question.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.9b00114DOI Listing

Publication Analysis

Top Keywords

secondary ion
12
time-of-flight secondary
8
ion mass
8
mass spectrometry
8
height measurement
8
topography
4
topography measurements
4
measurements high
4
high mass
4
mass resolution
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!