A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of tissue deformation during radiofrequency and microwave ablation procedures: Influence of output energy delivery. | LitMetric

Purpose: The purpose of this study was to quantitatively analyze tissue deformation during radiofrequency (RF) and microwave ablation for varying output energy levels.

Methods: A total of 46 fiducial markers which were classified into outer, middle, and inner lines were positioned into a single plane around an RF or microwave ablation applicator in each ex vivo bovine liver sample (8 cm × 6 cm × 4 cm, n = 18). Radiofrequency (500 kHz; ~35 W average) or microwave (2.4 GHz; 50-100 W output, ~35-70 W delivered) ablation was performed for 10 min (n = 4-6 each setting). CT images were acquired over the entire liver volume every 15 s. Principle strain magnitude and direction were determined from fiducial marker displacement. Normal and shear strain were then calculated such that negative strain denoted contraction and positive strain denoted expansion. Temporal variations, the final magnitudes, and angles of the strain were compared across energy delivery settings, using one-way ANOVA with post hoc Tukey's tests.

Results: On average, tissue strain rates peak at around 1 min and decayed exponentially over time. No evidence of tissue expansion was observed. The tissue strains from RF and 50 W, 75 W, and 100 W microwave ablation at 10 min were -8.5%, -38.9%, -54.4%, and -65.7%, respectively, from the inner region and -3.6%, -23.7%, -41.8%, and -44.3%, respectively, from the outer region. Negative strain magnitude was positively correlated to energy delivery in the inner region (Spearman's  = -0.99). Microwaves at higher powers (75-100 W) induced significantly more strain than at lower power (50 W) or after RF ablation (P < 0.01). Principal strain angles ranged from 0.8° to -8.1°, indicating that tissue deformed more in the direction transverse to the applicator than along the direction of the applicator.

Conclusions: The influence of output energy on tissue deformation during RF and microwave ablation was analyzed. Microwave ablation created significantly greater contraction than RF ablation with similar energy delivery. During microwave ablation, more contraction was noted at higher power levels and in proximity to the antenna. Contraction primarily transverse to the antenna produces ablation zones that are more elongated than the original tissue volume.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6739156PMC
http://dx.doi.org/10.1002/mp.13688DOI Listing

Publication Analysis

Top Keywords

microwave ablation
16
energy delivery
12
tissue deformation
8
deformation radiofrequency
8
radiofrequency microwave
8
output energy
8
strain
8
strain magnitude
8
negative strain
8
strain denoted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!