Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Left atrial appendage (LAA) closure with the Watchman device is increasingly used in patients with nonvalvular atrial fibrillation for stroke prevention. Though clinical trials have shown a similar combined risk of ischemic and hemorrhagic stroke, there is an increased risk of ischemic stroke in patients with a Watchman device compared with anticoagulation. Some ischemic strokes are related to a device-related thrombus (DRT), which may be attributable to delayed endothelialization of exposed fabric and metal.
Methods And Results: Patients undergoing Watchman LAA occlusion between January 2016 and June 2018 were enrolled in a prospective registry. From this cohort, 46 patients who had both transesophageal echocardiogram (TEE) and computed tomography (CT) at 45 days follow-up were selected for this study. The degree of LAA occlusion and type of leak were assessed by CT and TEE. TEE identified no patients with a significant (>5 mm) peri-device leak, 27 (58.6%) with nonsignificant peri-device leak (<5 mm), and 19 (41.4%) with complete occlusion. CT identified contrast in the LAA in 28 (60%) patients. However, in 10 (21.8%) of these patients, contrast entered the LAA through the fabric rather than around the device. No DRT were identified.
Conclusion: These data reveal that the Watchman device remains porous 6 weeks after implantation in a substantial percentage of patients, suggesting delayed endothelialization of the device. Cardiac CT may help to differentiate between peri-device and trans-fabric leak. Additional studies are required to test whether prolonged anticoagulation in patients with trans-fabric leak may help to reduce the risk of DRT and ischemic stroke.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.14053 | DOI Listing |