A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Video-based computer navigation in knee arthroscopy for patient-specific ACL reconstruction. | LitMetric

Purpose: The anterior cruciate ligament tear is a common medical condition that is treated using arthroscopy by pulling a tissue graft through a tunnel opened with a drill. The correct anatomical position and orientation of this tunnel are crucial for knee stability, and drilling an adequate bone tunnel is the most technically challenging part of the procedure. This paper presents the first guidance system based solely on intra-operative video for guiding the drilling of the tunnel.

Methods: Our solution uses small, easily recognizable visual markers that are attached to the bone and tools for estimating their relative pose. A recent registration algorithm is employed for aligning a pre-operative image of the patient's anatomy with a set of contours reconstructed by touching the bone surface with an instrumented tool.

Results: Experimental validation using ex-vivo data shows that the method enables the accurate registration of the pre-operative model with the bone, providing useful information for guiding the surgeon during the medical procedure. Experiments also demonstrate that the guided drilling of the tunnel leads to errors as low as 2.5 mm in the footprint and [Formula: see text] in orientation, which compares favourably to other works in the field.

Conclusion: The high accuracy and short time overhead evinced by the experimental validation combined with no additional incisions or capital equipment make this video-based computer-aided arthroscopy solution an appealing alternative to the existing approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-019-02021-0DOI Listing

Publication Analysis

Top Keywords

experimental validation
8
video-based computer
4
computer navigation
4
navigation knee
4
knee arthroscopy
4
arthroscopy patient-specific
4
patient-specific acl
4
acl reconstruction
4
reconstruction purpose
4
purpose anterior
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!