Background: Laptop computers are used in various places and situations. The number of laptop users experiencing musculoskeletal disorders (MSDs) has increased drastically due to, in part, inappropriate workstations.

Objective: To investigate the neck and shoulder postures, and muscle activity relative to perceived pain when using the laptop at a low-height table, sofa, and bed.

Methods: Twenty male participants aged 18-25 years were randomly assigned to perform laptop computer operation at 3 workstations for 10 minutes during which neck and shoulder angles, muscle activity, and pain were recorded by using an Electrogoniometer, Electromyography (EMG), and visual analog scale (VAS), respectively.

Results: Neck flexions when working at the sofa (18.6°±12.2°) and bed (17.2°±10.5°) were significantly (p < 0.05) greater than that at the low-height table (7.8°±6.5°). However, shoulder flexion when working at the low-height table (28.2°±13.0°) was significantly (p < 0.05) greater than that at the sofa (13.8°±8.6°) and bed (10.91°±7.8°). Working at the low-height table caused the shoulder flexor muscle activity to be significantly (p < 0.05) higher than working at the sofa and bed. Neck pain was reported during laptop computer use at the sofa and bed, and upper back pain when working at the low-height table.

Conclusions: High neck flexion and pain were found while working at sofa and bed, whereas high muscle activity at shoulder and upper back pain were found while working at the low-height table.

Download full-text PDF

Source
http://dx.doi.org/10.3233/WOR-192942DOI Listing

Publication Analysis

Top Keywords

neck shoulder
12
shoulder postures
8
postures muscle
8
relative perceived
8
perceived pain
8
pain laptop
8
laptop computer
8
low-height table
8
table sofa
8
muscle activity
8

Similar Publications

Background: Upper limb fractures significantly alter movement, impacting function and recovery. Three-dimensional motion analysis allows precise assessment of these changes.

Methods: Sixty patients were divided into four groups: shoulder, elbow, wrist fractures, and controls.

View Article and Find Full Text PDF

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Neck and shoulder pain (NSP) is a common issue among college students, yet no studies have linked digital device usage to NSP prevalence in China. This cross-sectional survey aimed to explore this relationship among students in Shanghai. A total of 6,000 students were randomly selected, with 4,848 (80.

View Article and Find Full Text PDF

Objectives: Edema after shoulder arthroscopic surgery poses concerns due to its potential complications such as compartment syndrome, nerve damage, and respiratory issues. This study aimed to investigate the acute accumulation of subcutaneous fluid after shoulder arthroscopy.

Methods: A prospective cohort study, providing Level III evidence was conducted on 50 patients undergoing arthroscopic shoulder surgery under interscalene block anaesthesia from September to December 2023.

View Article and Find Full Text PDF

Sensorless model-based tension control for a cable-driven exosuit.

Wearable Technol

December 2024

Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland.

Cable-driven exosuits have the potential to support individuals with motor disabilities across the continuum of care. When supporting a limb with a cable, force sensors are often used to measure tension. However, force sensors add cost, complexity, and distal components.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!