This is a report on the development of an automated precision load-based measurement setup for thermoelectric power (S) of different types of samples in the temperature range of 5-330 K. The problems in the old spring-based setup have been solved in this load-based setup. This setup takes nearly 4 h for each run, and the typical error is within 5%. High quality calibration has been demonstrated using high purity platinum wires and cylinders.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5090954 | DOI Listing |
Biomed Phys Eng Express
January 2025
Mindanao Radiation Physics Center, MSU-Iligan Institute of Technology, Andres Bonifacio Street Tibanga, Iligan City, Lanao Norte, 9200, PHILIPPINES.
To accurately model and validate the 6 MV Elekta Compactlinear accelerator using the Geant4 Application for Tomographic Emission (GATE). In particular, this study focuses on the precise calibration and validation of critical parameters, including jaw collimator positioning, electron source nominal energy, flattening filter geometry, and electron source spot size, which are often not provided in technical documentation. Methods: Simulation of the Elekta Compact6 MV linear accelerator was performed using the Geant4 Application for Tomographic Emission (GATE) v.
View Article and Find Full Text PDFJ Magn Reson
January 2025
São Carlos Institute of Physics, University of São Paulo São Carlos São Paulo Brazil.
Among the numerous measurements carried out during a well-logging procedure, the Nuclear Magnetic Resonance (NMR) assessment is one of the fundamental analyses in determining the economic viability of a well for the oil industry. Nowadays, two reliable approaches, Wireline Logging (WL) and Logging While Drilling (LWD), stand out. WL comprises the acquisition of NMR data under static conditions.
View Article and Find Full Text PDFMicrosc Microanal
January 2025
EMAT, University of Antwerp, Groenenborgerlaan 171 2020, Antwerp, Belgium.
The challenge of imaging low-density objects in an electron microscope without causing beam damage is significant in modern transmission electron microscopy. This is especially true for life science imaging, where the sample, rather than the instrument, still determines the resolution limit. Here, we explore whether we have to accept this or can progress further in this area.
View Article and Find Full Text PDFLangmuir
January 2025
Laboratoire de Physique des Solides, CNRS, Université Paris Saclay, 91405 Orsay, France.
Controlling the structure of polymer solutions near a solid surface is crucial for many industrial processes as it significantly impacts solution flow and influences slip at the interface. To date, only a few techniques have been developed to experimentally investigate this type of interface at the nanometric scale of solid/liquid interactions. In this study, we probe the interface between a smooth sapphire surface and a semidilute polystyrene solution, using neutron reflectivity.
View Article and Find Full Text PDFMethods
January 2025
CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal; LABBELS - Associate Laboratory, University of Minho, Braga/Guimarães, Portugal. Electronic address:
Measurements of changes in fluorescence signal is one of the most commonly applied methods for studying protein-ligand affinities. These measurements are generally carried out using cuvettes in spectrofluorometers, which can only measure one sample at a time. This makes screening procedures for multiple ligands and proteins extremely laborious, as each protein must be measured with multiple ligand concentrations, and usually in triplicate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!