Prism arrays arranged to form a slightly open alligator mouth were found to focus incident X-rays, as with increasing distance from the object symmetry axis these rays hit an increasing number of refracting prism tips. Such an object is then formally a refractive lens. Due to the strong energy dependence of the refractive index of material for X-rays a refractive X-ray lens is chromatically focusing. The attractive feature of the alligator lens is the inherent zoomability possible as the mouth can easily be opened or closed. However, the required tolerances for the jaw rotations and the jaw positioning are so stringent, that the routine use of such systems has not been reported yet. This study will show that the related technical problems can be overcome by proper object fabrication. In fact the here presented objects can already be aligned in the production stage. Then the assembly can be made with simple tools. And the zooming is achieved by just a simple rotation. The transmission through the devices was found to be as expected, and thus performance-wise these objects can directly compete with other refractive X-ray focusing systems.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.016781DOI Listing

Publication Analysis

Top Keywords

refractive x-ray
8
zooming x-rays
4
x-rays single
4
single rotation
4
rotation x-ray
4
x-ray prism
4
prism zoom
4
zoom lenses
4
lenses xpzl
4
xpzl prism
4

Similar Publications

Background: This study evaluates retinal oxygen saturation and vessel density within the macula and correlates these measures in controls and subjects with type 2 diabetes (DM) with (DMR) and without (DMnR) retinopathy. Changes in retinal oxygen saturation have not been evaluated regionally in diabetic patients.

Methods: Data from seventy subjects (28 controls, 26 DMnR, and 16 DMR were analyzed.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the correlation between axial length (AL) and retinal oxygen dynamic parameters in adult patients.

Methods: This was an observational cross-sectional study with 79 Chinese adults with myopia aged 18 to 37 years. All participants underwent AL measurements, cycloplegic refraction, and other ophthalmic examinations.

View Article and Find Full Text PDF

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

BMC Ophthalmol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China.

Purpose: To evaluate the predictive accuracy of 11 intraocular lens (IOL) calculation formulas in eyes with an axial length (AL) less than 22.00 mm.

Methods: New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7-10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude.

View Article and Find Full Text PDF

Simulations of the Potential for Diffraction Enhanced Imaging at 8 keV using Polycapillary Optics.

Biomed Phys Eng Express

January 2025

Physics Department, University at Albany, 1400 Washington Ave, Albany, New York, 12222-0100, UNITED STATES.

Conventional x-ray radiography relies on attenuation differences in the object, which often results in poor contrast in soft tissues. X-ray phase imaging has the potential to produce higher contrast but can be difficult to utilize. Instead of grating-based techniques, analyzer-based imaging, also known as diffraction enhanced imaging (DEI), uses a monochromator crystal with an analyzer crystal after the object.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!