Microlenses have wide applications for light beam focusing or shaping in micro-optical systems. However, it remains challenging for conventional microfabrication methods to rapidly fabricate arrays of microlenses with complex profiles like lens-on-lens structures. In this paper, we present the rapid fabrication of polymer microlenses with lens-on-lens structures by using a digital optical μ-printing technology. An improved dynamic optical exposure method is developed to directly and precisely fabricate polymer top-lensed microlenses (TLMLs). Arrays of TLMLs with either elongated focal depth or two separate foci have been numerically investigated and experimentally demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.018376DOI Listing

Publication Analysis

Top Keywords

optical μ-printing
8
polymer top-lensed
8
lens-on-lens structures
8
rapid optical
4
μ-printing polymer
4
top-lensed microlens
4
microlens array
4
microlenses
4
array microlenses
4
microlenses wide
4

Similar Publications

Veterinary ophthalmology-Ocular surgery.

Vet Ophthalmol

January 2025

Southeast Animal Eye Specialists, Newnan, GA, USA.

View Article and Find Full Text PDF

Ocular surface chemical injuries often result in permanent visual impairment and necessitate complex, long-term treatments. Immediate and extensive irrigation serves as the first-line intervention, followed by various therapeutic protocols applied throughout different stages of the condition. To optimize outcomes, conventional regimens increasingly incorporate biological agents and surgical techniques.

View Article and Find Full Text PDF

This prospective cohort study is aimed to investigate circadian variations in corneal parameters, focusing on sleep-deprived subjects. Sixty-four healthy individuals (age range: 21-76 years) actively participated in this study, undergoing examinations at least five times within a 24-hour timeframe. The analysis encompassed keratometric parameters of the cornea's front (F) and back (B) surfaces, refractive power in flattest and steepest axes (K1, K2), astigmatism (Astig) and its axis (Axis), aspheric coefficient (Asph), corneal pachymetry values of thinnest corneal thickness (Pachy Min) and corneal thickness in the center of the pupil (Pachy Pupil), volume relative to the 3 and 10 mm corneal diagonal (Vol D3, Vol D10) and surface variance index (ISV).

View Article and Find Full Text PDF

Introduction: This study compared the clinical outcomes of allogenic cultured limbal epithelial transplantation (ACLET) and cultivated oral mucosal epithelial transplantation (COMET) in the management of limbal stem cell deficiency (LSCD).

Methods: Forty-one COMET procedures in 40 eyes and 69 ACLET procedures in 54 eyes were performed in the Corneoplastic Unit of Queen Victoria Hospital, East Grinstead. Data were examined for demographics, indications, ocular surface stability, absence of epithelial defect, ocular surface inflammation, visual outcomes, and intra- and postoperative complications.

View Article and Find Full Text PDF

Mitochondrial membrane protein-associated neurodegeneration (MPAN) is a rare neurodegenerative disorder characterized by spastic paraplegia, parkinsonism and psychiatric and/or behavioral symptoms caused by variants in gene encoding chromosome-19 open reading frame-12 (C19orf12). We present here seven patients from six unrelated families with detailed clinical, radiological, and genetic investigations. Childhood-onset patients predominantly had a spastic ataxic phenotype with optic atrophy, while adult-onset patients were presented with cognitive, behavioral, and parkinsonian symptoms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!