A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Portable Blood (Gas) Analyzer in a Helicopter Emergency Medical Service. | LitMetric

Portable Blood (Gas) Analyzer in a Helicopter Emergency Medical Service.

Air Med J

Department of Anesthesiology, VU University Medical Center, Amsterdam, The Netherlands; Helicopter Emergency Medical Service Life Liner 1, VU University Medical Center, Amsterdam, The Netherlands. Electronic address:

Published: July 2020

Introduction: In prehospital helicopter emergency medical services (HEMS), the medical team frequently manages critical patients with only limited, noninvasive monitoring options on-site and during HEMS transport. To gain deeper insight into the patient's pathology and to track prehospital treatment effects, a point-of-care blood (gas) analyzer appears desirable also in HEMS. Thus, we hypothesized that prehospital blood (gas) analysis is feasible in the HEMS setting.

Methods: A prehospital evaluation of a portable blood (gas) analyzer (i-Stat 1; Abbott, Chicago, IL) with appropriate laboratory cartridges was performed within the Dutch HEMS Lifeliner 1, serving a region of ∼4.5 million inhabitants. Venous blood (gas) measurements were performed in our HEMS collective in both trauma and nontrauma cases.

Results: The HEMS team identified benefits (eg, portability and speed) and limitations (eg, a narrow operational temperature range) regarding the tested blood (gas) analyzer. Regarding the actual blood (gas) results, the team collected results without major abnormalities but also cases identifying major pathologies, including several cases of marked acidosis, refractory hypoglycemia, or severe anemia.

Conclusion: In conclusion, portable blood (gas) analysis proved feasible in an HEMS operation but with relevant limitations. Future studies will have to show how these limitations can be overcome and how the implementation of portable blood (gas) analyzers may support improved patient outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amj.2019.04.006DOI Listing

Publication Analysis

Top Keywords

blood gas
36
portable blood
16
gas analyzer
16
gas
9
helicopter emergency
8
emergency medical
8
hems
8
blood
8
gas analysis
8
feasible hems
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!