Despite motion artifacts are a major source of noise in fNIRS infant data, how to approach motion correction in this population has only recently started to be investigated. Homer2 offers a wide range of motion correction methods and previous work on simulated and adult data suggested the use of Spline interpolation and Wavelet filtering as optimal methods for the recovery of trials affected by motion. However, motion artifacts in infant data differ from those in adults' both in amplitude and frequency of occurrence. Therefore, artifact correction recommendations derived from adult data might not be optimal for infant data. We hypothesized that the combined use of Spline and Wavelet would outperform their individual use on data with complex profiles of motion artifacts. To demonstrate this, we first compared, on infant semi-simulated data, the performance of several motion correction techniques on their own and of the novel combined approach; then, we investigated the performance of Spline and Wavelet alone and in combination on real cognitive data from three datasets collected with infants of different ages (5, 7 and 10 months), with different tasks (auditory, visual and tactile) and with different NIRS systems. To quantitatively estimate and compare the efficacy of these techniques, we adopted four metrics: hemodynamic response recovery error, within-subject standard deviation, between-subjects standard deviation and number of trials that survived each correction method. Our results demonstrated that (i) it is always better correcting for motion artifacts than rejecting the corrupted trials; (ii) Wavelet filtering on its own and in combination with Spline interpolation seems to be the most effective approach in reducing the between- and the within-subject standard deviations. Importantly, the combination of Spline and Wavelet was the approach providing the best performance in semi-simulation both at low and high levels of noise, also recovering most of the trials affected by motion artifacts across all datasets, a crucial result when working with infant data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neuroimage.2019.06.056 | DOI Listing |
Sci Rep
December 2024
Department of Radiology, Seoul National University Hospital, 101 Daehangno, Jongno-gu, Seoul, 03080, Korea.
Ultrasound (US) is a widely used technique for liver disease but has limitations in distinguishing tumors. This study evaluates the clinical efficacy of fluctuational imaging (FLI), a new US method that detects the fluttering sign in liver tumors. We conducted a prospective exploratory study with 120 participants diagnosed with liver tumors through histopathology or standard imaging.
View Article and Find Full Text PDFAbdom Radiol (NY)
December 2024
Cincinnati Children's Hospital Medical Center, Cincinnati, USA.
Objectives: Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.
Methods: Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2).
Adv Radiat Oncol
February 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah.
Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.
Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.
AJNR Am J Neuroradiol
December 2024
From the Department of Diagnostic Medicine, Dell Medical School at The University of Texas at Austin, Austin, TX, USA (C.Y.H.), Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA (N.S., G.A., Q.W., P.C., M.A., J.G.P., B.R.G., P.R.T., G.D.H.), Department of Medicine, Indiana University School of Medicine, Indianapolis, IN, USA (E.C., P.R.T., S.A.P.), Stark Neuroscience Research Institute, Indiana University School of Medicine, Indianapolis, IN, USA (P.R.T., S.A.P.), and the Department of Radiology at Texas Children's Hospital, Houston, TX, USA (S.F.K.).
Background And Purpose: There are multiple MRI perfusion techniques, with limited available literature comparing these techniques in the grading of pediatric brain tumors. For efficiency and limiting scan time, ideally only one MRI perfusion technique can be used in initial imaging. We compared DSC, DCE, and IVIM along with ADC from DWI for differentiating high versus low grade pediatric brain tumors.
View Article and Find Full Text PDFUrogynecology (Phila)
December 2024
Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA.
Importance: Functional near-infrared spectroscopy (fNIRS) is a noninvasive technique used to quantify prefrontal cortex (PFC) neuroexcitation. The PFC is involved in the decision to void, and dysfunction in the region has been associated with overactive bladder (OAB). This study demonstrates neuroexcitation differences in the brain region associated with the decision to void (prefrontal cortex) using noninvasive fNIRS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!