Purpose: To report 5-year outcomes of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) with a central graft thickness intended to be <100 μm.

Methods: This retrospective, consecutive, interventional case series included 354 eyes with endothelial decompensation due to various causes (Fuchs endothelial dystrophy, pseudophakic or aphakic bullous keratopathy, failed previous graft, herpetic endothelitis, or buphthalmos). Donor tissue was prepared using the microkeratome-assisted double-pass technique aiming at a graft thickness <100 μm. The Descemet membrane was stripped under air. The graft was delivered into the anterior chamber using the pull-through technique through a 3.2-mm clear corneal incision using a modified Busin glide. The best spectacle-corrected visual acuity (BSCVA), endothelial cell loss, graft survival rates, and immunologic rejection rates were evaluated.

Results: Follow-up data at 1, 2, 3, and 5 years after UT-DSAEK were collected from 214, 172, 147, and 105 eyes, respectively. After excluding eyes with comorbidities, BSCVA better than or equal to  20/20 was recorded in 36.3%, 37.4%, 46.4%, and 53.4% of eyes, respectively, whereas BSCVA better than or equal to 20/40 was documented in 95.5%, 95.3%, 96.0%, and 96.6% of eyes, respectively. The mean endothelial cell loss was 35.4%, 42.3%, 43.3%, and 52.3%; Kaplan-Meier graft survival probability was 99.1%, 96.2%, 94.2%, and 94.2%, and Kaplan-Meier cumulative probability of a rejection episode was 3.4%, 4.3%, 5%, and 6.9% at 1, 2, 3, and 5 years, respectively.

Conclusions: UT-DSAEK grafts allow excellent 5-year outcomes, including BSCVA, endothelial cell density, and survival rates comparable with those recorded post-Descemet membrane endothelial keratoplasty, but with a higher immunologic rejection rate.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000001999DOI Listing

Publication Analysis

Top Keywords

outcomes ultrathin
8
ultrathin descemet
8
descemet stripping
8
stripping automated
8
automated endothelial
8
endothelial keratoplasty
8
five-year outcomes
4
keratoplasty purpose
4
purpose report
4
report 5-year
4

Similar Publications

Objectives: This report illustrates the digital interdisciplinary management of a case presenting with diastemata, a retained primary tooth, microdontia, and hypodontia. Esthetic crown lengthening and ultrathin veneers optimized the natural dentition and achieved a stable, minimally-invasive, and esthetically-pleasing outcome.

Clinical Considerations: Reduction guides were digitally-designed and 3D-printed for guided crown lengthening and dental veneer preparation.

View Article and Find Full Text PDF

The current study investigates and compares the biological effects of ultrathin conformal coatings of zirconium dioxide (ZrO) and vanadium pentoxide (VO) on osteoblastic MG-63 cells grown on TiO nanotube layers (TNTs). Coatings were achieved by the atomic layer deposition (ALD) technique. TNTs with average tube diameters of 15, 30, and 100 nm were fabricated on Ti substrates (via electrochemical anodization) and were used as primary substrates for the study.

View Article and Find Full Text PDF

Purpose: To assess the safety and the efficacy of the "Sub-400 corneal cross-linking (CXL) protocol" for progressive keratoconus (KC) in ultrathin corneas.

Methods: The study included thirty four patients with progressive KC, who underwent CXL using the "Sub-400" protocol due to intraoperative thinnest corneal pachymetry ranging from 295 to 398 μm after epithelial removal. After the epithelium was removed, the following ultraviolet A irradiation was applied at a fluence of 3 mW/cm and the duration was adjusted based on the specific corneal stromal thickness.

View Article and Find Full Text PDF

Background: The Orsiro and Genoss DES stents are biodegradable polymer drug-eluting stents (DESs) with ultrathin struts.

Objective: To investigate the safety and efficacy of these two ultrathin DESs in real-world practice.

Methods: From a single-center prospective registry, we included 751 and 931 patients treated with the Genoss DES and Orsiro stents, respectively.

View Article and Find Full Text PDF

The challenge in developing molecule-based electronic materials lies in the uncontrollable or unpredictable nature of their crystal structures, which are crucial for determining both electrical properties and thin-film formability. This review summarizes the findings of a research project focused on the systematic development of crystalline organic semiconductors (OSCs) and organic ferroelectrics by integrating experimental, computational, and data sciences. The key outcomes are as follows: 1) Data Science: We developed a method to identify promising materials from crystal structure databases, leading to the discovery of unique molecule-based ferroelectrics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!