A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Lateral Antebrachial Cutaneous Nerve as Autologous Graft for Mini-Invasive Corneal Neurotization (MICORNE). | LitMetric

Purpose: We describe the first case of a novel surgical technique of mini-invasive corneal neurotization (MICORNE) using the lateral antebrachial cutaneous nerve as a graft nerve and the contralateral supraorbital nerve as a donor nerve in a herpetic patient with a neurotrophic keratopathy (NK).

Methods: A MICORNE procedure was performed in a 32-year-old man with a 5-year history of herpes simplex virus (HSV)-related NK in the right eye (RE). Visual acuity and corneal sensation were assessed over 9 months of follow-up. HSV-1 and HSV-2 genomes were screened preoperatively and postoperatively in the patient's tears using the quantitative polymerase chain reaction technique. A high does of the oral antiviral prophylaxis was prescribed during the follow-up.

Results: Preoperative best-corrected visual acuity was 20/200 in the RE. A Cochet-Bonnet esthesiometer revealed complete corneal anesthesia (<5 mm ie, >15.9 g/mm) in all quadrants in a scarred and neovascularized cornea. Twelve months after the procedure, the visual acuity of the RE was 20/80 and corneal sensitivity had increased to 40 mm, that is, 0.8 g/mm (superior quadrant), 35 mm, that is, 1 g/mm (inferior quadrant), 40 mm (temporal quadrant), 35 mm, that is, 1 g/mm (nasal quadrant), and 40 mm (centrally). We observed no clinical recurrence of herpes, and HSV was not detected in tears during the follow-up period.

Conclusions: We report the first case of MICORNE, a novel surgical technique of corneal neurotization in a herpetic patient with NK. Despite the potential risk of viral recurrence, our patient showed dramatic improvement in corneal sensation and visual acuity.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000002004DOI Listing

Publication Analysis

Top Keywords

visual acuity
16
corneal neurotization
12
lateral antebrachial
8
antebrachial cutaneous
8
cutaneous nerve
8
mini-invasive corneal
8
neurotization micorne
8
novel surgical
8
surgical technique
8
herpetic patient
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!