While epidemiological data support the link between reduced heart rate variability (HRV) and a multitude of pathologies, the mechanisms underlying changes in HRV and disease progression are poorly understood. Even though we have numerous rodent models of disease for mechanistic studies, not being able to reliably measure HRV in conscious, freely moving rodents has hindered our ability to extrapolate the role of HRV in the progression from normal physiology to pathology. The sheer number of heart beats per day (>800,000 in mice) makes data exclusion both time consuming and daunting. We sought to evaluate an RR interval exclusion method based on percent (%) change of adjacent RR intervals. Two approaches were evaluated: % change from "either" and "both" adjacent RR intervals. The data exclusion method based on standard deviation (SD) was also evaluated for comparison. Receiver operating characteristic (ROC) curves were generated to determine the performance of each method. Results showed that exclusion based on % change from "either" adjacent RR intervals was the most accurate method in identifying normal and abnormal RR intervals, with an overall accuracy of 0.92-0.99. As the exclusion value increased (% change or SD), the sensitivity (correctly including normal RR intervals) increased exponentially while the specificity (correctly rejecting abnormal RR intervals) decreased linearly. Compared to the SD method, the "either" approach had a steeper rise in sensitivity and a more gradual decrease in specificity. The intersection of sensitivity and specificity where the exclusion criterion had the same accuracy in identifying normal and abnormal RR intervals was 10-20% change for the "either" approach and ∼ 1 SD for the SD-based exclusion method. Graphically (tachogram and Lorenz plot), 20% change from either adjacent RR interval resembled the data after manual exclusion. Finally, overall (SDNN) and short-term (rMSSD) indices of HRV generated using 20% change from "either" adjacent RR intervals as the exclusion criterion were closer to the manual exclusion method with lower subject-to-subject variability than those generated using the 2 SD exclusion criterion. Thus, 20% change from "either" adjacent RR intervals is a good criterion for data exclusion for reliable 24-h time domain HRV analysis in rodents.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562196 | PMC |
http://dx.doi.org/10.3389/fphys.2019.00693 | DOI Listing |
Clin Oral Investig
January 2025
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.
Objectives: To develop a platform including a deep convolutional neural network (DCNN) for automatic segmentation of the maxillary sinus (MS) and adjacent structures, and automatic algorithms for measuring 3-dimensional (3D) clinical parameters.
Materials And Methods: 175 CBCTs containing 242 MS were used as the training, validating and testing datasets at the ratio of 7:1:2. The datasets contained healthy MS and MS with mild (2-4 mm), moderate (4-10 mm) and severe (10- mm) mucosal thickening.
Neural Netw
January 2025
Hebei Key Laboratory of Marine Perception Network and Data Processing, Northeastern University (Qinhuangdao), Qinhuangdao 066004, China. Electronic address:
Entity alignment (EA) is a typical strategy for knowledge graph integration, aiming to identify and align different entity pairs representing the same real object from different knowledge graphs. Temporal Knowledge Graph (TKG) extends the static knowledge graph by introducing timestamps. However, since temporal knowledge graphs are constructed based on their own data sources, this usually leads to problems such as missing or redundant entity information in the temporal knowledge graph.
View Article and Find Full Text PDFPLoS One
January 2025
Tactical Research Unit, Bond University, Robina, QLD, Australia.
Police tactical group (PTG) officers respond to the most demanding and high-risk police situations. As such, PTG personnel require exceptional physical fitness, and selection for employment often evaluates fitness both directly and indirectly. While heart rate (HR) is often used to measure physical effort, heart rate variability (HRV) may be a valuable tool for measuring stress holistically.
View Article and Find Full Text PDFBehav Sci (Basel)
December 2024
Philosophy and Social Science Laboratory of Reading and Development in Children and Adolescents, Ministry of Education, & Center for Studies of Psychological Application, School of Psychology, South China Normal University, Guangzhou 510631, China.
Pitch is a fundamental element in music. While most previous studies on musical pitch have focused on musicians, our understanding of musical pitch perception in non-musicians is still limited. This study aimed to explore how Mandarin-speaking listeners who did not receive musical training perceive and categorize musical pitch.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Wuhan National Laboratory for Optoelectronics, Next Generation Internet Access National Engineering Laboratory, and Hubei Optics Valley Laboratory, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, 430074, China.
We propose and validate a novel optical semantic transmission scheme using multimode fiber (MMF). By leveraging the frequency sensitivity of intermodal dispersion in MMFs, we achieve high-dimensional semantic encoding and decoding in the frequency domain. Our system maps symbols to 128 distinct frequencies spaced at 600 kHz intervals, demonstrating a seven-fold increase in capacity compared to conventional communication encoding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!