An intriguing simple toy, commonly known as the Notched Stick, is discussed as an example of a "vibrot", a device designed and built to yield conversion of mechanical vibrations into a rotational motion. The toy, that can be briefly described as a propeller fixed on a stick by means of a nail and free to rotate around it, is investigated from both an experimental and a numerical point of view, under various conditions and settings, to investigate the basic working principles of the device. The conversion efficiency from vibration to rotational motion turns out to be very small, or even not detectable at all, whenever the propeller is tightly connected to the stick nail and perfectly axisymmetrical with respect to the nail axis; the small effects possibly observed can be ascribed to friction forces. In contrast, the device succeeds in converting vibrations into rotations when the propeller center of mass is not aligned with the nail axis, a condition occurring when either the nail-propeller coupling is not tight or the propeller is not completely axisymmetrical relative to the nail axis. The propeller rotation may be induced by a process of parametric resonance for purely vertical oscillations of the nail, by ordinary resonance if the nail only oscillates horizontally or, finally, by a combination of both processes when nail oscillations take place in an intermediate direction. Parametric resonance explains the onset of rotations also when the weight of the propeller is negligible. In contrast with what is commonly claimed in the literature, the possible elliptical motion of the nail, due to a composition of two harmonic motions of the same frequency imposed along orthogonal directions, seems unnecessary to determine the propeller rotation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594746 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0218666 | PLOS |
J Orthop
August 2025
Department of Orthopaedic Surgery, Oita University Hospital, Japan.
Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.
Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.
Purpose Of The Study: Intraarticular fractures of the distal femur rank among the most severe musculoskeletal injuries. Various treatment options, such as plate osteosynthesis or retrograde nailing, can be employed. This study aims to evaluate the clinical outcomes and complications of intraarticular distal femoral fractures treated with retrograde femoral nail, with particular emphasis on C3 fractures.
View Article and Find Full Text PDFFront Immunol
December 2024
Department of Experimental Medicine, University of Rome "Tor Vergata", Rome, Italy.
Introduction: Fungi, including , may be a trigger or exacerbate psoriasis, especially in difficult to treat (DTT) areas, through the activation of IL-17/23 axis.
Methods: In this study, seventy patients with DDT psoriasis were enrolled to evaluate species and/or other opportunistic fungi colonization rate at baseline (T0) and the impact of apremilast on fungal load, clinical outcome, serum cytokine levels and biochemical serum profile of patients after 16, 24 and 52 weeks of treatment.
Results: In our population, 33 (47%) patients were colonized by spp.
World Neurosurg
January 2025
Department of Neurological Surgery, The University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Background: Simultaneous C1 and C2 fractures are increasingly common, but contemporary series are limited.
Methods: All patients with traumatic fractures of both C1 and C2 admitted to an academic trauma center from 2012 to 2022 were retrospectively analyzed. Multivariable regression was used to identify characteristics relevant to management and outcomes.
J Orthop Case Rep
December 2024
Department of Orthopaedic and Trauma Surgery, Hospital General Universitario Gregorio Marañon, C. Dr. Esquerdo 46, 28007, Madrid, Spain.
Introduction: Extra-articular deformity is that located proximal to the femoral epicondyles or distal to the neck of the fibula. In patients with gonarthrosis associated with extra-articular deformity, a different evaluation and approach will be necessary at the time of planning the arthroplasty. 3D planning and printing techniques have had a major impact on pre-operative planning, allowing the production of custom guides at low cost and in an accessible way.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!