Unlabelled: Pupose: To experimentally compare the visual acuity and the subjective perception of different types of multifocal intraocular lenses (IOL) using a VirtIOL device/simulator in a group of volunteers with artephakia.

Material And Methods: This was an experimental study involving a total of 20 volunteers with artephakia (35 eyes). Each volunteer rated 5 types of IOLs, 4 presbyopia-correcting IOLs - WIOL-CF, Tecnis Symphony ZXR00, Acrysof IQ PanOptix TFNT00, M-flex 630 F, and as a reference lens, we used the monofocal IOL Acrysof SA60AT. The corrected distance visual acuity (CDVA), distance corrected intermediated visual acuity (DCIVA) and distance corrected near visual acuity (DCNVA) were measured. Additionally, volunteers evaluated the quality of vision under normal or changed lighting conditions, and ranked IOL on scale from 1 to 5.

Results: The CDVA evaluated using the VirtIOL device was very good for all tested IOLs (0.04-0.09 log MAR) with minimum differences. However, CDVA without simulator (-0.01 logMAR) was statistically significantly better in all cases. DCIVA was also very similar in each of the investigated IOLs, surprisingly even with monofocal IOL (0.21-0.23 logMAR), without using simulator the DCIVA was statistically significantly worse (0.36 logMAR). The DCNVA was the best for PanOptix intraocular lens (0.22 logMAR); M-flex, Symphony and WIOL-CF lenses had comparable results (0.31-0.34 logMAR). Again, surprisingly similar results were obtained with the use of monofocal IOL (0.36 ± 0.14). Subjective perception of vision through the IOLs was best rated for the monofocal control IOL, whereas Symphony, WIOL-CF and M-flex did not show any statistically significant difference either with or without glare. All tested IOLs were statistically significantly better if compared to PanOptix with or without glare.

Conclusion: Simulation of vision through IOLs using VirtIOL simulator allows to compare different models of multifocal IOLs from the viewpoint of visual acuity and subjective perception. However, some caution should be exercised when evaluating the results, given that in our experiments, the monofocal IOL achieved relatively good results at near distance, which does not correspond to clinical experience. On the contrary, from the comparison of the results of CDVA without and with VirtIOL, it is obvious that visual acuity is slightly adversely affected by added optics.

Download full-text PDF

Source
http://dx.doi.org/10.31348/2018/6/1DOI Listing

Publication Analysis

Top Keywords

visual acuity
24
monofocal iol
16
subjective perception
12
quality vision
8
intraocular lenses
8
acuity subjective
8
iols
8
distance corrected
8
tested iols
8
statistically better
8

Similar Publications

Retinal detachment after acute retinal necrosis: a retrospective analysis of hospitalized patients.

Jpn J Ophthalmol

January 2025

Department of Visual Science and Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Purpose: To review hospitalized patients with Acute Retinal Necrosis (ARN) and investigate factors associated with subsequent retinal detachment (RD).

Study Design: Retrospective.

Methods: The study included 40 patients (42 eyes), categorized into non-RD (23 eyes) and RD (19 eyes) groups.

View Article and Find Full Text PDF

Background: While vaccination remains crucial in mitigating the impact of the COVID-19 pandemic, several ocular adverse events has been reported, including Acute Zonal Occult Outer Retinopathy (AZOOR) complex.

Case Presentation: A 31-year-old female presented declined best corrected visual acuity (BCVA) and flashes in both eyes three days following second recombinant mRNA COVID-19 vaccine (Moderna). Fundus autofluorescence (FAF) illustrated speckled hyper-AF lesions surrounding right eye torpedo maculopathy site and hyper-AF lesions in the left macula.

View Article and Find Full Text PDF

Background: The psychometric properties of the Convergence Insufficiency Symptom Survey (CISS) have been previously determined across the younger adult population. This study investigated the psychometric properties of the CISS in presbyopic adults via classical and Rasch analysis.

Methods: A total of 100 presbyopic individuals (40-60 years) were selected with far and near acuity of 20/20 with their habitual spectacles; 50 had convergence insufficiency and 50 had normal binocular vision.

View Article and Find Full Text PDF

We employed high-resolution fMRI to distinguish the impacts of anisometropia and strabismus amblyopia on the evoked ocular dominance (OD) response. Sixteen amblyopic participants (8 females) plus 8 individuals with normal vision (1 female), participated in this study for whom, we measured the difference between the response to stimulation of the two eyes, across areas V1-V4.In controls, the evoked OD response formed the expected striped pattern within V1.

View Article and Find Full Text PDF

Dual inhibition of the angiopoietin (Ang)/Tie and vascular endothelial growth factor (VEGF) signalling pathways in patients with retinal diseases, such as neovascular age-related macular degeneration (nAMD) and diabetic macular oedema (DME), may induce greater vascular stability and contribute to increased treatment efficacy and durability compared with treatments that only target the VEGF pathway. Faricimab, a bispecific intravitreal agent that inhibits both VEGF and Ang-2, is the first injectable ophthalmic drug to achieve treatment intervals of up to 16 weeks in Phase 3 studies for nAMD and DME while exhibiting improvements in visual acuity and retinal thickness. Data from real-world studies have supported the safety, visual and anatomic benefits and durability of faricimab, even in patients who were previously treated with other intravitreal agents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!