A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Facile Non-Enzymatic Electrochemical Sensing for Glucose Based on CuO-BSA Nanoparticles Modified GCE. | LitMetric

Transition-metal nanomaterials are very important to non-enzymatic glucose sensing because of their excellent electrocatalytic ability, good selectivity, the fact that they are not easily interfered with by chloride ion (Cl), and low cost. However, the linear detection range needs to be expanded. In this paper, CuO-bovine serum albumin (BSA) core-shell nanoparticles (NPs) were synthesized for the first time in air at room temperature by a facile and green route. The structure and morphology of CuO-BSA NPs were characterized. The as-prepared CuO-BSA NPs were used to modify the glassy carbon electrode (GCE) in a Nafion matrix. By using cyclic voltammetry (CV), the influence from scanning speed, concentration of NaOH, and load of CuO-BSA NPs for the modified electrodes was probed. CuO-BSA NPs showed direct electrocatalytic activity for the oxidation of glucose in 50 mM NaOH solution at 0.6 V. The chronoamperometry result showed this constructing sensor in the detection of glucose with a lowest detection limit of 0.4 μM, a linear detection range up to 10 mM, a high sensitivity of 1144.81 μAmMcm and reliable anti-interference property to Cl, uric acid (UA), ascorbic acid (AA), and acetaminophen (AP). CuO-BSA NPs are promising nanostructures for the fabrication of non-enzymatic glucose electrochemical sensing devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6631518PMC
http://dx.doi.org/10.3390/s19122824DOI Listing

Publication Analysis

Top Keywords

cuo-bsa nps
20
electrochemical sensing
8
non-enzymatic glucose
8
linear detection
8
detection range
8
cuo-bsa
6
nps
6
glucose
5
facile non-enzymatic
4
non-enzymatic electrochemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!