A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is There a Correlation Between Preoperative or Postoperative Vitamin D Levels with Pseudarthrosis, Hardware Failure, and Revisions After Lumbar Spine Fusion? | LitMetric

Background: Vitamin D deficiency is a well-known cause of postoperative complications in patients undergoing orthopedic surgery. Orthopedic complications seen in vitamin D deficiency include nonunion, pseudarthrosis, and hardware failure. We seek to investigate the relationship between vitamin D deficiency and outcomes after lumbar spinal fusions.

Methods: A retrospective patient chart review was conducted at a single center for all patients who underwent lumbar spinal fusions from January 2015 to September 2017 with preoperative or postoperative vitamin D laboratory values. We recorded demographics, social history, medications, pre-existing medical conditions, bone density (dual-energy x-ray absorptiometry) T-scores, procedural details, 1-year postoperative Visual Analog Score (VAS), documented pseudarthrosis, revisions, and hardware failure. A total of 150 patients were initially included in the cohort for analysis.

Results: Overall, preoperative and postoperative vitamin D levels were not significantly associated with a vast majority of the patient characteristics studied, including comorbidities, medications, or surgical diagnoses (P > 0.05). Age at surgery was significantly associated with vitamin D levels; older patients had higher serum levels of vitamin D both preoperatively (P = 0.03) and postoperatively (P = 0.01). Those with a higher average body mass index had lower vitamin D in both groups (P = 0.02). Vitamin D levels were not significantly associated with rates of postoperative pseudarthrosis, revision, or hardware complications (P > 0.05). VAS pain score at 1 year and smoking status preoperatively or postoperatively were not associated with vitamin D levels (P > 0.05).

Conclusions: Both preoperative and postoperative vitamin D levels were not significantly associated with an increased or decreased risk of pseudarthrosis, revision surgery, hardware failure, or 1-year VAS pain score after lumbar spine fusion surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2019.06.109DOI Listing

Publication Analysis

Top Keywords

vitamin levels
24
preoperative postoperative
16
postoperative vitamin
16
hardware failure
16
vitamin
12
vitamin deficiency
12
levels associated
12
pseudarthrosis hardware
8
lumbar spine
8
lumbar spinal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!