The purpose of this study was to assess the accuracy and reliability of a continuous blood glucose monitoring system (artificial endocrine pancreas; STG-55, Nikkiso, Tokyo, Japan) during pediatric cardiopulmonary bypass surgery. Twenty-five pediatric patients scheduled to undergo cardiovascular surgery with cardiopulmonary bypass (age 4 months to 11 years; body weight 5.6-59.7 kg) were enrolled. The glucose sensor line of the artificial endocrine pancreas was connected to the venous side of the cardiopulmonary bypass circuit and used for continuous blood glucose monitoring. We obtained 192 samples for blood gas assessment from the cardiopulmonary bypass circuit, and i-STAT (Abbott, East Windsor, NJ, USA) was used for conventional blood glucose assessment. The accuracies of continuous glucose measurements (STG-55) and conventional intermittent glucose measurements (i-STAT) during cardiopulmonary bypass were compared by means of Clarke error grid analysis. The results were divided into five zones, A, B, C, D, and E, and 78.6% of paired measurements were in zone A, while 21.4% were in zone B. We confirmed that the results of this continuous blood glucose monitoring system for cardiopulmonary bypass during pediatric cardiovascular surgery were highly reliable. An artificial endocrine pancreas may facilitate the safe use of intensive insulin therapy during pediatric cardiovascular surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-019-01111-9DOI Listing

Publication Analysis

Top Keywords

cardiopulmonary bypass
28
blood glucose
20
continuous blood
16
glucose monitoring
16
artificial endocrine
12
endocrine pancreas
12
cardiovascular surgery
12
accuracy reliability
8
reliability continuous
8
glucose
8

Similar Publications

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Background: Low oxygen delivery (DO2) on cardiopulmonary bypass has been associated with acute kidney injury. We sought to determine the association of intraoperative DO2, postoperative length of stay, and major postoperative events.

Methods: DO2 values were calculated in 845 patients after initiation, and every 30 minutes on bypass.

View Article and Find Full Text PDF

Aneurysms of the superior vena cava are rare vascular malformations of systemic veins. This report presents the case of a 27-year-old woman with an incidental finding of mediastinal shadow widening on the chest roentgenogram that was confirmed by computed tomographic angiography to be a superior vena cava saccular aneurysm >4 cm in diameter. Surgical resection was recommended on the basis of aneurysmal size and shape and was performed through median sternotomy by using cardiopulmonary bypass.

View Article and Find Full Text PDF

Background: Cardiac surgery patients are at increased risk for venous thromboembolism (VTE). Prevention is the most critical strategy to reduce VTE-associated morbidity and death. However, there is a lack of data on the optimal approach to VTE prophylaxis in this population of high-risk patients.

View Article and Find Full Text PDF

Serum Lidocaine Levels in Adult Patients Undergoing Cardiac Surgery With del Nido Cardioplegia.

Ann Thorac Surg Short Rep

June 2024

Division of Cardiothoracic Surgery, Northwell Health, Manhasset, New York.

Background: Lidocaine in del Nido cardioplegia solution prolongs the refractory period of cardiomyocytes, yielding a longer arrest per dose. Serum lidocaine concentrations >8 mg/L are associated with seizure and cardiotoxicity. We evaluated serum lidocaine concentrations in patients receiving del Nido solution during cardiac surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!