Graft Perforation by a Spinal Bony Spur: An Unusual Cause of Late Bleeding after Thoracoabdominal Aorta Replacement.

Korean J Thorac Cardiovasc Surg

Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.

Published: June 2019

We report an unusual case of delayed bleeding after open surgical repair of a thoracoabdominal aortic aneurysm. A 79-year-old man developed a massive retroperitoneal hematoma 49 days after Crawford type III thoracoabdominal aorta replacement. During emergency surgery, a tear was found in the prosthetic vascular graft caused by a sharp bony spur arising from the second lumbar vertebral body. This rare, but potentially lethal, complication indicates that attention should be paid to sharp bony structures during open repair of the descending aorta.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6559183PMC
http://dx.doi.org/10.5090/kjtcs.2019.52.3.186DOI Listing