Atomically resolved probe-type scanning tunnelling microscope for use in harsh vibrational cryogen-free superconducting magnet.

Ultramicroscopy

Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory of the Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China; CASmF Sci.&Tech. Ltd. (), Hefei, Anhui 230088, People's Republic of China; Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China; Collaborative Innovation Center for Artificial Microstructure and Quantum Control, Nanjing University, Nanjing 210093, People's Republic of China; Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China. Electronic address:

Published: October 2019

We present a probe-type scanning tunnelling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature insert (VTI) is installed in the magnet and the STM is housed in the VTI, a lowest temperature of 1.6 K can be achieved, at which the STM still operates well. We tested the STM in an 8 T superconducting magnet cooled with a pulse-tube cryocooler and obtained atomically resolved graphite and NbSe images as well as the scanning tunnelling spectrum (i.e., dI/dV spectrum) data of the latter near its critical temperature, which show the formation process of the superconducting gap as a function of temperature. The drifting rates of the STM at 1.6 K in the X-Y plane and Z direction are 1.15 and 1.71 pm/min, respectively. Noise analysis for the tunnelling current shows that the amplitudes of the dominant peaks (6.84 and 10.25 Hz) are as low as 1.5 pA.Hz when we set the current to 0.5 nA and open the feedback loop. This is important as a cryogen-free magnet system has long been considered too harsh for any atomic resolution measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2019.06.006DOI Listing

Publication Analysis

Top Keywords

scanning tunnelling
12
superconducting magnet
12
atomically resolved
8
probe-type scanning
8
tunnelling microscope
8
harsh vibrational
8
vibrational cryogen-free
8
cryogen-free superconducting
8
atomic resolution
8
magnet system
8

Similar Publications

Effects of Nanosilica on the Properties of Ultrafine Cement-Fly Ash Composite Cement Materials.

Nanomaterials (Basel)

December 2024

School of Civil Engineering and Architecture, Henan University, Kaifeng 475000, China.

The increasing incidence of structural failures, such as cracks and collapses, in rock masses within mines, tunnels, and other civil engineering environments has attracted considerable attention among scholars in recent years. Grouting serves as a principal solution to these issues. The Renlou Coal Mine in the Anhui Province is used as a case study to evaluate the effectiveness of nanosilica (NS) as an additive in ultrafine cement (UC), introducing a novel grouting material for practical applications.

View Article and Find Full Text PDF

Tunable Quantum Confinement in Individual Nanoscale Quantum Dots via Interfacial Engineering.

ACS Nano

December 2024

Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal University, Beijing 100875, China.

Introducing quantum confinement has shown promise to enable control of charge carriers. Although recent advances make it possible to realize confinement from semiclassical regime to quantum regime, achieving control of electronic potentials in individual nanoscale quantum dots (QDs) has remained challenging. Here, we demonstrate the ability to tune quantum confined states in individual nanoscale graphene QDs, which are realized by inserting nanoscale monolayer WSe islands in graphene/WSe heterostructures via interfacial engineering.

View Article and Find Full Text PDF

Objective: There are many advantages to stabilize the posterior pelvic ring injuries with a transiliac-transsacral (TITS) screw percutaneously. To identify the correct entry point and insert a guidewire accurately for a TITS screw, we propose a method of specifying the optimal entry point, and introduce a technique of enabling freehand placement of a guidewire with fluoroscopic guidance.

Methods: In this retrospective study, 116 patients who underwent pelvic CT scans and pelvic lateral radiographs at our institution from January 2020 to April 2022 were enrolled.

View Article and Find Full Text PDF

Jumping Dynamics of Cyanomethyl Radicals on Corrugated Graphene/Ru(0001) Substrates.

J Phys Chem C Nanomater Interfaces

December 2024

Instituto IMDEA Nanociencia, Calle Faraday 9, 28049 Madrid, Spain.

Graphene adsorbed on Ru(0001) has been widely used as a template for adsorbing and isolating molecules, assembling organic-molecule structures with desired geometric and electronic properties and even inducing chemical reactions that are challenging to achieve in the gas phase. To fully exploit the potential of this substrate, for example, by being able to tune a graphene-based catalyst to perform optimally under specific conditions, it is crucial to understand the factors and mechanisms governing the molecule-substrate interaction. To contribute to this effort, we have conducted a combined experimental and theoretical study of the adsorption of cyanomethyl radicals (-CHCN) on this substrate below room temperature by performing scanning tunneling microscopy experiments and density functional theory simulations.

View Article and Find Full Text PDF

Electroisomerization blinking of an azobenzene derivative molecule.

Nanotechnology

December 2024

IEMN, avenue Poincaré, Villeneuve-d'Ascq, Hauts-de-France, 59652, FRANCE.

We report here the reversibility and bistability of the switching behavior in an azobenzene derivative induced by the bias applied by a Scanning-Tunneling Microscopy (STM) tip, at low temperature and in ultra-high vacuum environment. This cis-to-trans and trans-to-cis switching were observed during STM imaging in either polarity at +2V or -2V, on a sub-second time scale. This results in a blinking effect visible on STM images, corresponding to the reversible switching of the azobenzene molecule under the applied STM bias through an electric field induced process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?