A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Autologous Transfusion of Blood Aspirated during Suction Decompression in Clipping of Large or Giant Cerebral Aneurysm. | LitMetric

The suction decompression (SD) method, which proactively aspirates the blood flowing into the aneurysm and reduces the internal pressure of the aneurysm, is useful for clipping surgery of large and giant cerebral aneurysm. However, there has been little discussion on re-utilization of blood aspirated during SD. This study aimed to examine the safety, convenience, and usefulness of autologous transfusion of aspirated blood using a transfusion bag. At the time of craniotomy, the cervical carotid artery is fully exposed. An angiocatheter sheath was inserted into the carotid artery and placed in the internal carotid artery. In SD, blood was aspirated from the sheath at a constant speed and quickly stored in a blood transfusion storage bag. Blood aspiration was repeated with a new syringe; once the transfusion bag was full, the blood was re-administered to the patient. Changes in vital sign and hemoglobin/hematocrit values before and after SD were examined in five cases performed in this procedure. The aspirated blood volumes of five cases ranged from 130 to 400 mL, and all aspirated blood was successfully re-transfused. There was no critical change in vital sign, and no significant decrease in the hemoglobin/hematocrit value. No findings suggestive of complications of thrombus formation, infection, and hemolysis were noted. Re-transfusion of aspirated blood during SD using a transfusion bag is a simple and safe method, which can minimize potential risk of re-utilizing aspirated blood, and enables the safe and easy execution of SD regardless of aspirated blood volume.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753252PMC
http://dx.doi.org/10.2176/nmc.tn.2018-0299DOI Listing

Publication Analysis

Top Keywords

aspirated blood
24
blood
13
blood aspirated
12
blood transfusion
12
transfusion bag
12
carotid artery
12
aspirated
9
autologous transfusion
8
suction decompression
8
large giant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!