Background: Due to it being tangential to the distal femoral axis, the anteromedial portal presents significant risk of causing iatrogenic damage, and of producing tunnels that are too short for optimal osseointegration. Flexible reamers were developed to eliminate the need for knee hyperflexion and offer better-controlled orientation of the femoral tunnel. We aimed to compare the anteversion and length of femoral tunnels drilled using flexible reamers to those drilled using rigid reamers.

Methods: Between May 2012 and December 2013, all patients receiving ACL reconstruction performed by one surgeon were operated on using either a rigid or a flexible reamer from the same supplier (Versi-Tomic® system, Stryker, Kalamazoo, Michigan). The height of each patient was recorded, and the length and anteversion of the femoral tunnels were measured intra-operatively and on true lateral radiographs, respectively.

Results: Thirty-seven patients underwent operations using the rigid instrumentation, and 43 using the flexible instrumentation. There was no statistically significant difference between the two groups in either sex or height (p = n.s.). The patients operated on using the rigid instrumentation had tunnels anteverted by 18.6° ± 6° and 33.6 ± 2.9 mm long. Those operated on using the flexible instrumentation had tunnels anteverted by 40° ± 2° and 41.1 ± 3.57 mm long. Both anteversion and tunnel length were significantly greater for tunnels drilled using the flexible instrumentation (p < 0.001).

Conclusions: This study demonstrated that flexible reamers produce significantly more anteverted and longer femoral tunnels during ACL reconstruction than rigid reamers. Clinical studies remain necessary to assess the outcomes of ACL reconstruction using flexible reamers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6589149PMC
http://dx.doi.org/10.1186/s40634-019-0198-0DOI Listing

Publication Analysis

Top Keywords

flexible instrumentation
16
anteversion length
8
length femoral
8
femoral tunnel
8
acl reconstruction
8
rigid flexible
8
flexible reamers
8
femoral tunnels
8
tunnels drilled
8
drilled flexible
8

Similar Publications

Study Design: Retrospective Cohort Study.

Objectives: Flexibility radiographs such as traction or bending radiographs are essential in preoperative imaging to assess for curve flexibility and to estimate the amount of operative correction in order to determine the type and length of instrumentation in growth-accompanying scoliosis treatment. Both traction and bending radiographs are controversially discussed in the literature.

View Article and Find Full Text PDF

The primary method of treatment for patients suffering from drug-resistant focal-onset epilepsy is resective surgery, which adversely impacts neurocognitive function. Radio frequency (RF) ablation and laser ablation are the methods with the most promise, achieving seizure-free rates similar to resection but with less negative impact on neurocognitive function. However, there remains a number of concerns and open technical questions about these two methods of thermal ablation, with the primary ones: (1) heating; (2) hemorrhage and bleeding; and (3) poor directionality.

View Article and Find Full Text PDF

Background: Endotracheal intubation (ETI) is a life-saving procedure that must be accurately carried on to guard against complications. Presbyopia leads to difficulty in viewing close objects and may obstacle proper intubation even with the best hands.

Purpose: This study supposed that the use of video-laryngoscope (VL) may provide better intubation conditions for presbyopic anesthetists and targets to evaluate the neonates and infants' intubation success rates (ISR) by anesthetists aged ≥ 45 years using the C-MAC VL compared to the standard laryngoscope (SL).

View Article and Find Full Text PDF

Introduction: This systematic review and meta-analysis assess the impact of the XP-endo Shaper (XPS) on postoperative pain following root canal treatment (RCTs) and compare its efficacy with other endodontic systems.

Methods: A comprehensive literature search was conducted in MEDLINE, Web of Science, Embase, and the Cochrane Library from January 2000 to August 2024. Randomized controlled trials using XPS and reporting postoperative pain were included.

View Article and Find Full Text PDF

Template-assembly activation of primer exchange reaction for on-site and sensitive detection of copper ions in blood.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

The First Clinical Medical College, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, PR China. Electronic address:

The sensitive and accurate detection of copper ions is crucial for public health, medical research, and environmental monitoring. In this study, we developed a sensor based on template-assembly activation of the primer exchange reaction (PER) for the on-site detection of copper ions in blood. Copper ions triggered the assembly of two template fragments into a hairpin structure via a click-chemistry reaction, activating the PER.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!