Background: Increasing attention is being paid to the treatment of shale gas fracturing wastewater, including flowback and produced water (FPW). Energy-efficient pretreatment technologies suitable for desalinating and reusing FPW are of paramount importance.
Objectives: This work focused on enhanced fouling alleviation of ultrafiltration (UF) as a pretreatment for desalinating shale gas FPW in Sichuan Basin, China. The UF fouling behaviors under various backwash water sources or coagulant dosages were evaluated, and membrane surface characteristics were correlated with UF fouling. The feasibility of Fourier transform infrared (FTIR) microscope mapping technique in quantifying UF fouling was also assessed.
Methods: Various backwash water sources, including UF permeate, ultrapure water, nanofiltration (NF) permeate, reverse osmosis (RO) permeate, RO concentrate and forward osmosis (FO) draw solution, were used to clean UF membranes fouled by shale gas FPW. The UF fouling behaviors were characterized by total and non-backwashable fouling rates. Membrane surface characteristics were analyzed by scanning electron microscopy (SEM), total tension surface and FTIR spectra.
Results: Protein-like substances in terms of fluorescence intensity in the backwash water decreased with the order of UF permeate, RO concentrate, NF permeate, RO permeate and FO draw solution. Compared with UF permeate backwashing, alleviated UF fouling was observed by using demineralized backwash water including ultrapure water and RO permeate, irrespective of hollow fiber and flat-sheet membranes. NF permeate and RO concentrate after NF used as backwash water resulted in low and comparable membrane fouling with that in integrated coagulation-UF process under optimal dosage. Among the backwash water tested, FO draw solution backwashing corresponded to the lowest UF fouling rates, which were even lower than that in the presence of coagulant under optimal dosage. The superiority of these backwash water sources to UF permeate was further confirmed by SEM images and FTIR spectra. The residual foulant mass on membrane surface and the total surface tension correlated well with non-backwashable and total fouling rates, respectively.
Conclusions: FTIR microscopy was a powerful surface mapping technique to characterize UF membrane fouling caused by shale gas FPW. Backwash water sources significantly influenced the fouling of UF membranes. In the integrated UF-NF-RO or UF-FO process, RO concentrate or FO draw solution were proposed as backwash water to enhance UF fouling control and decrease waste discharge simultaneously.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.envint.2019.05.063 | DOI Listing |
Membranes (Basel)
January 2025
DVGW-Research Center at the Engler-Bunte-Institute, Water Chemistry and Water Technology, Karlsruhe Institute of Technology, Engler-Bunte-Ring 9, 76131 Karlsruhe, Germany.
Short-chain fatty acids (SCFAs) are valuable metabolic intermediates that are produced during dark fermentation of sludge, which, when capitalized on, can be used as chemical precursors for biotechnological applications. However, high concentrations of solids with SCFAs in hydrolyzed sludge can be highly detrimental to downstream recovery processes. This pilot-scale study addresses this limitation and explores the recovery of SCFAs from primary sludge into a particle-free permeate through a combination of chamber filter-press (material: polyester; mesh size: 100 µm) and cross-flow microfiltration (material: α-AlO; pore size: 0.
View Article and Find Full Text PDFEnviron Res
December 2024
School of Environmental Science and Engineering, Tiangong University, State Key Laboratory of Separation Membranes and Membrane Processes, Binshui West Road 399, Xiqing District, Tianjin, 300387, PR China; Cangzhou Institute of Tiangong University, Cangzhou 061000, China. Electronic address:
Biofouling has been one of the major challenges impacting the long-term stable operation of ultrafiltration processes. Irreversible biofouling is considerably more harmful than reversible biofouling. Conductive membrane, as a new technology to effectively mitigate membrane fouling, lack research of controlling irreversible biofouling.
View Article and Find Full Text PDFWater Res
December 2024
Institute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. Electronic address:
Calcium (Ca)-enhanced organic matter (OM) fouling of nanofiltration (NF) membranes leads to reduced flux during desalination and requires frequent cleaning. Fouling mechanisms are not fully understood, which limits the development of targeted fouling control methods. This study employed synchrotron-based X-ray fluorescence (XRF) and X-ray absorption near-edge structure (XANES) spectroscopy to quantify the spatial distribution and mass of Ca deposition as well as changes in the Ca coordination environment characteristic of specific fouling mechanisms, respectively.
View Article and Find Full Text PDFMembranes (Basel)
December 2024
School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai 264209, China.
The issue of environmental pollution caused by wastewater discharge from fruit juice production has attracted increasing attention. However, the cost-effectiveness of conventional treatment technology remains insufficient. In this study, a gravity-driven membrane bioreactor (GDMBR) was developed to treat real fruit juice wastewater from secondary sedimentation at pressures ranging from 0.
View Article and Find Full Text PDFHeliyon
December 2024
Research Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de València, Camino de Vera, s/n, 46022, Valencia, Spain.
The textile industry is one of the largest water consumers, and, as a result of its activity, it generates tons of wastewater. In this research, forward osmosis has been employed to tackle the critical need of treating textile wastewater. The HFFO2 membrane (Aquaporin) was used to process large volumes of real cotton dyeing wastewater, wool dyeing wastewater, and several types of textile end-of-pipe wastewater.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!