Objective: To analyze rate and type of complications in cochlear implant (CI) recipients receiving immunosuppressive therapy following solid organ transplant (SOT).

Study Design: Retrospective case series. English language literature review.

Setting: Tertiary referral center.

Intervention: Cochlear implantation surgery following solid organ transplantation (SOT) and immunosuppressive therapy.

Methods: Data of patients who received CI after SOT and with at least one year of follow up were reviewed. Main outcome measures were the rate and type of complications, classified as major (requiring a second surgical procedure) and minor (requiring medical therapy). A search was performed in PubMed database on January 2019 using the keywords: organ transplant; cochlear implant, complications, deafness, solid organ transplant, immunosuppressive therapy. Only studies reporting on patients who have been implanted after the transplant procedure and with a follow up period of at least 1 year were considered. Final analysis was performed on pooled data.

Results: Four patients received CI surgery following SOT. Age at treatment ranged from 40 to 47 years (mean 44.25 years). Follow-up after implantation averaged 5.25 years (range 1-10 years), without complications. Review of the available literature on the subject yielded seven papers; a total of 26 procedures in 22 patients satisfied inclusion criteria. Pooled data from the present series and from the literature were analyzed; the global rate of complications was 16.6%, with 10% major (3 of 30 procedures) and 6.6% minor (2 of 30 procedures). The three reported cases of major complications appear unrelated to SOT. Major complications were found in one case over 16 procedures in pediatric patients (6.2%), while in adults the percentage raised to 14.3% (2/14 procedures).

Conclusions: Cochlear implantation is a safe and effective intervention, even during immunosuppressive therapy after organ transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00405-019-05524-3DOI Listing

Publication Analysis

Top Keywords

solid organ
16
cochlear implantation
12
organ transplantation
12
immunosuppressive therapy
12
organ transplant
12
review literature
8
rate type
8
type complications
8
cochlear implant
8
patients received
8

Similar Publications

Friend or Foe? Safety and Efficacy of Hepatitis B Viremic Solid Organ Allograft into Seronegative Recipients.

J Am Coll Surg

January 2025

Cincinnati Research in Outcomes and Safety in Surgery (CROSS) Research Group. Department of Surgery, University of Cincinnati College of Medicine, Cincinnati, Ohio.

Background: Long-term outcomes of HBV nucleic acid test (NAT)-positive (+) allograft use in seronegative liver transplant (LT) and kidney transplant (KT) recipients remains unknown despite being incorporated into practice by select centers. This study compares long-term outcomes between HBV NAT+ and NAT-negative (-) allografts in seronegative recipients.

Study Design: All recipients of an HBV core antibody-positive (HBcAb+) LT or KT were prospectively evaluated at a single transplant center from 6/2015-3/2023 and compared by NAT status.

View Article and Find Full Text PDF

Image Guided Percutaneous Robotic Interventions for Solid Organs.

Tech Vasc Interv Radiol

December 2024

Department of Interventional Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Interventional Radiology, Miami Cardiac and Vascular Institute, Baptist Health South Florida, Miami, FL; Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Cancer Center Amsterdam, AMS, The Netherlands. Electronic address:

Robotic systems for minimally invasive procedures, particularly in interventional oncology, have advanced significantly, especially for percutaneous interventions guided by CT, Cone-beam CT, and MRI. These systems, which include needle-guiding and needle-driving robots, enhance the precision of procedures like biopsy and tumor ablation. Needle-guiding robots plan and align the needle, while needle-driving robots autonomously advance it, improving needle placement accuracy, enabling out-of-plane insertion, and reducing radiation exposure.

View Article and Find Full Text PDF

Recent developments and applications of solid membrane in chiral separation.

J Chromatogr A

January 2025

Shanghai Engineering Research Center of Organ Repair, Joint International Research Laboratory of Biomaterials and Biotechnology in Organ Repair (Ministry of Education), School of Medicine, Shanghai University, Shanghai 200444, China; Shanghai Key Laboratory of Bio-Energy Crops, School of Life Sciences, Shanghai University, Shanghai 200444, China. Electronic address:

Chirality is a fundamental property in nature, and chiral molecules are closely related to human health and the origin of life. Therefore, the exploration and preparation of optically active compounds of paramount importance. Membrane separation is a large-scale and continuous separation technique that has been developing quickly in recent years.

View Article and Find Full Text PDF

Microbial molecules, metabolites, and malignancy.

Neoplasia

January 2025

Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA; Department of Molecular Genetics and Microbiology, University of Florida College of Medicine, Gainesville, FL, USA. Electronic address:

Research elucidating the role of the microbiome in carcinogenesis has grown exponentially over the past decade. Initially isolated to associative studies on colon cancer development, the field has expanded to encompass nearly every solid and liquid malignancy that may afflict the human body. Investigations are rapidly progressing from association to causation and one particular area of causal effect relates to microbial metabolites and how they influence cancer development, progression, and treatment response.

View Article and Find Full Text PDF

Background: With continued improvement in patient outcomes following solid organ transplant (SOT), more SOT recipients may benefit from hip arthroplasty. This study sought to compare the perioperative complications and survivorship of SOT recipients undergoing hip arthroplasty for elective care versus for fracture.

Methods: A single-institution retrospective review yielded 95 hip arthroplasty procedures (80 patients) performed between August 2016 and May 2023 with a mean follow-up of 35 months.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!