The sensitivity to subject motion is one of the major challenges in functional MRI (fMRI) studies in which a precise alignment of images from different time points is required to allow reliable quantification of brain activation throughout the scan. Especially the long measurement times and laborious fMRI tasks add to the amount of subject motion found in typical fMRI measurements, even when head restraints are used. In case of moving subjects, prospective motion correction can maintain the relationship between spatial image information and subject anatomy by constantly adapting the image slice positioning to follow the subject in real time. Image-based prospective motion correction is well-established in fMRI studies and typically computes the motion estimates based on a volume-to-volume image registration, resulting in low temporal resolution. This study combines fMRI using simultaneous multislice imaging with multislice-to-volume-based image registration to allow sub-TR motion detection with subsequent real-time adaption of the imaging system. Simultaneous multislice imaging is widely used in fMRI studies and, together with multislice-to-volume-based image registration algorithms, enables computing suitable motion states after only a single readout by registering the simultaneously excited slices to a reference volume acquired at the start of the measurement. The technique is evaluated in three human BOLD fMRI studies (n = 1, 5, and 1) to explore different aspects of the method. It is compared to conventional, volume-to-volume-based prospective motion correction as well as retrospective motion correction methods. Results show a strong reduction in retrospectively computed residual motion parameters of up to 50% when comparing the two prospective motion correction techniques. An analysis of temporal signal-to-noise ratio as well as brain activation results shows high consistency between the results before and after additional retrospective motion correction when using the proposed technique, indicating successful prospective motion correction. The comparison of absolute tSNR values does not show an improvement compared to using retrospective motion correction alone. However, the improved temporal resolution may provide improved tSNR in the presence of more exaggerated intra-volume motion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2019.06.042DOI Listing

Publication Analysis

Top Keywords

motion correction
36
prospective motion
24
image registration
16
fmri studies
16
motion
15
simultaneous multislice
12
multislice imaging
12
retrospective motion
12
correction
9
functional mri
8

Similar Publications

Background: Various methods exist to correct for intrafraction motion (IFM) of the prostate during radiotherapy. We sought to characterize setup corrections in our practice informed by the TrueBeam Advanced imaging package, and analyze factors associated with IFM.

Methods: 132 men received radiation therapy for prostate cancer with a volumetric modulated arc therapy technique.

View Article and Find Full Text PDF

4D flow cardiac magnetic resonance in pediatric congenital heart disease: Insights from over four years of clinical practice.

Clin Imaging

January 2025

Institute of Clinical sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Pediatric Radiology, The Queen Silvia Children's Hospital, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.

Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD.

Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.

View Article and Find Full Text PDF

Split tendon transfer of the posterior tibialis for spastic equinovarus foot deformity: Does tendon routing impact post-operative ankle kinematics?

Gait Posture

January 2025

Department of Orthopaedics, BC Children's Hospital, 4500 Oak St, Vancouver, BC V6H 3N1, Canada; The Motion Lab, Sunny Hill Health Centre, 4480 Oak St, Vancouver, BC V6H 3N1, Canada; University of British Columbia, Faculty of Medicine, Department of Orthopaedics, 317 - 2194 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada.

Background: Split tendon transfer of the posterior tibialis (SPOTT) is a surgical procedure in which the split posterior tibialis tendon is transferred posterior to the fibula (PO) with insertion on the peroneus brevis tendon to rebalance the forces across the hindfoot. Routing of the split tendon through the interosseous membrane (IO) is a variation with the potential benefit of augmenting ankle dorsiflexion in swing.

Research Question: Does IO routing improve ankle dorsiflexion in swing and/or varus in stance compared to PO routing?

Methods: A retrospective chart review was completed to identify forty-two patients who underwent a SPOTT procedure for equinovarus foot deformity.

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Background: Orthopaedic surgical intervention in children with Charcot-Marie-Tooth (CMT) often includes triceps surae lengthening (TSL) and foot procedures to address instability and pain due to equinus and cavovarus deformities. These surgeries may unmask underlying weakness in this progressive disease causing increased calcaneal pitch and excessive dorsiflexion in terminal stance leading to crouch. The purpose of this study was to evaluate changes in ankle function during gait following TSL surgery in children with CMT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!