Sense of touch is a major part of man's communication with their environment. Artificial skins can help robots to have the same sense of touch, especially for their social interactions. This paper presents a pressure mapping sensing using piezo-resistive fabric to represent aspects of the sense of touch. In past few years' electrical impedance tomography (EIT) is considered to be able offer a good alternative for artificial skin in particular for its ease of adaptation for large area skin compared to individual matrix based sensors. The EIT has also very good temporal performance in data collection allowing for monitoring of fast responses to touch stimulation, enabling a truly real time touch sensing. Electromechanical responses of a conductive fabric can be exploited using EIT to create a low cost and large area touch sensing. Such electromechanical properties are often very complex, so to improve the imaging resolution and touch visibility an artificial intelligent (AI) was used in addition to the state of the art spatio-temporal imaging algorithm. This work demonstrates a step towards an integrated seamless skin with large area sensing in dynamical settings, closer to natural human skin's behaviour. For the first time a dynamical touch sensing are studies by means of a spatio-temporal based electrical impedance tomography (EIT) imaging on a conductive fabric. The experimental results demonstrated the successful results by a combined AI with dynamical EIT imaging results in single and multiple points of touch.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6586820 | PMC |
http://dx.doi.org/10.1038/s41598-019-45484-6 | DOI Listing |
Lab Chip
January 2025
Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Rome, Italy.
Microfluidic impedance cytometry (MIC) is a label-free technique that characterizes individual flowing particles/cells based on their interaction with a multifrequency electric field. The technique has been successfully applied in different scenarios including life-science research, diagnostics, and environmental monitoring. The aim of this review is to illustrate the fascinating opportunities enabled by the integration of MIC with other microfluidic tools.
View Article and Find Full Text PDFNPJ Digit Med
January 2025
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
Monitoring fluid intake and output for congestive heart failure (CHF) patients is an essential tool to prevent fluid overload, a principal cause of hospital admissions. Addressing this, bladder volume measurement systems utilizing bioimpedance and electrical impedance tomography have been proposed, with limited exploration of continuous monitoring within a wearable design. Advancing this format, we developed a conductivity digital twin from radiological data, where we performed exhaustive simulations to optimize electrode sensitivity on an individual basis.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah, Iran.
This study introduces the development of a highly sensitive label-free electrochemical immunosensor specifically designed to detect prostate-specific antigen (PSA). A glassy carbon electrode (GCE) coated with Au nanoparticles/polyhedral hollow CoCu bimetallic sulfide (CuCoS) was employed as a sensing interface for the fixation of the monoclonal anti-PSA antibody. The nanoarchitectures enhanced the capacity for loading prostate-specific antibodies (Ab) and effectually boosted electrical conductivity leading to enhance the electrochemical signal and greater sensitivity for the detection of PSA.
View Article and Find Full Text PDFFuture Cardiol
January 2025
Department of Internal Medicine, Dow University of Health Sciences, Karachi, Pakistan.
Background: Implantable cardioverter-defibrillators (ICDs) are essential for reducing sudden cardiac death in patients at risk of ventricular arrhythmias. The choice of ICD lead - single-coil or dual-coil - can influence device performance and patient outcomes. This meta-analysis evaluates the comparative efficacy and safety of single-coil versus dual-coil ICD leads to inform clinical decision-making.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!