A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-dimensional measurement and registration accuracy of a third-generation optical tracking system for navigational maxillary orthognathic surgery. | LitMetric

Three-dimensional measurement and registration accuracy of a third-generation optical tracking system for navigational maxillary orthognathic surgery.

Oral Surg Oral Med Oral Pathol Oral Radiol

Department of Oral and Maxillofacial Surgery, Oral Science Research Center, Yonsei University, College of Dentistry, Seoul, Republic of Korea. Electronic address:

Published: September 2019

Objective: The purpose of this study was to evaluate the accuracy of an optical tracking system during reference point localization, measurement, and registration of skull models for navigational maxillary orthognathic surgery.

Study Design: Accuracy was first evaluated on the basis of the position recording discrepancy at a static point and at 2 points of fixed lengths. Ten reference points were measured on a skull model at 7 different locations, and their measurements were compared with predicted positions by using 4 registration methods. Finally, positional tracking of reference points for simulated maxillary surgery was performed and compared with laser scan data.

Results: The average linear measurement discrepancy was 0.28 mm, and the mean measurement discrepancy with the 5 registered cranial points was 1.53 mm. The average measurement discrepancy after maxillary surgery was 1.91 mm (for impaction) and 1.56 mm (for advancement). The registration discrepancy in jitter and point registration on the y-axis was significantly greater than on the other axes.

Conclusions: The optical tracking system seems clinically acceptable for precise tracking of the maxillary position during navigational orthognathic surgery, notwithstanding the chance of greater measurement error on the y-axis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.oooo.2019.01.008DOI Listing

Publication Analysis

Top Keywords

optical tracking
12
tracking system
12
measurement discrepancy
12
measurement registration
8
navigational maxillary
8
maxillary orthognathic
8
orthognathic surgery
8
reference points
8
maxillary surgery
8
registration
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!