Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Recent terror attacks and assassinations involving highly toxic chemical weapons have stressed the importance of sufficient respiratory protection of medical first responders and receivers. As full-face respirators cause perceptual-motor impairment, they not only impair vision but also significantly reduce speech intelligibility. The recent introduction of electronic voice projection units (VPUs), attached to a respirator, may improve communication while wearing personal respiratory protection.
Objective: To determine the influence of currently used respirators and VPUs on medical communication and speech intelligibility.
Methods: 37 trauma anaesthetists carried out an evaluation exercise of six different respirators and VPUs including one control. Participants had to listen to audio clips of a variety of sentences dealing with scenarios of emergency triage and medical history taking.
Results: In the questionnaire, operators stated that speech intelligibility of the Avon C50 respirator scored the highest (mean 3.9, ±SD 1.0) and that the Respirex Powered Respiratory Protective Suit (PRPS) NHS-suit scored lowest (1.6, 0.9). Regarding loudness the C50 plus the Avon VPU scored highest (4.1, 0.7), followed by the Draeger FPS-7000-com-plus (3.4, 1.0) and the Respirex PRPS NHS-suit scored lowest (2.3, 0.8).
Conclusions: We found that the Avon C50 is the preferred model among the tested respirators. In our model, electronic voice projection modules improved loudness but not speech intelligibility. The Respirex PRPS NHS-suit was rated significantly less favourably in respect of medical communication and speech intelligibility.