A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of shoulder ultrasound examination for diagnosis of rotator cuff pathologies: a single-center retrospective study. | LitMetric

AI Article Synopsis

  • The study investigates the effectiveness of shoulder ultrasonography (US) in diagnosing shoulder pathologies, particularly rotator cuff tears, compared to MRI findings.
  • Results show that US has high sensitivity (86%) and specificity (82%) for full-thickness supraspinatus tears, but significantly lower for partial-thickness tears (38% sensitivity).
  • The analysis included 86 patients from a tertiary care center, with US proving reliable for full-thickness tears but less accurate for partial-thickness, demonstrating the need for careful interpretation in clinical practice.

Article Abstract

Background: Shoulder pathologies need accurate diagnosis for best management and treatment provided to patients.

Objective: Determine the diagnostic sensitivity, specificity and accuracy of shoulder ultrasonography (US).

Design: Retrospective, analytical.

Setting: Tertiary care center in Riyadh, Saudi Arabia.

Patients And Methods: We included all shoulder exams performed between January 2010 and December 2016 that met the inclusion criteria. Data was collected retrospectively from the a picture archiving and communication system and patient records. The patients were evaluated using US for the presence of rotator cuff tears and classified into intact, full-thickness tear, partial-thickness tear, tendinosis, subacromial/subdeltoid bursitis and acromioclavicular joint degenerative changes. The US findings were correlated with the shoulder MRI study findings. The time interval between the US examination and MRI ranged from 0 to 180 days (6 months).

Main Outcome Measures: To compare the sensitivity, specificity and accuracy of shoulder US studies in the detection of rotator cuff pathologies in comparison to MRI findings.

Sample Size And Characteristics: 86 (60 females, 26 male), mean age 53.7 years (range, 19-85).

Results: The sensitivity, specificity and accuracy of US for the detection of full-thickness supraspinatus tears compared with those of MRI were 86%, 82% and 83%, respectively. The sensitivity, specificity and accuracy of US for the detection of partial-thickness supraspinatus tears compared with those of MRI were 38%, 70% and 58%, respectively. Overall PPV, NPV, sensitivity, specificity and accuracy of US for the detection of full-thickness tears compared with those of MRI were 35%, 97%, 78%, 83% and 83%, respectively. For partial-thickness tears, the overall PPV, NPV, sensitivity, specificity and accuracy of US compared with those of MRI were 51%, 60%, 51%, 60% and 56%, respectively.

Conclusion: Overall, US has high sensitivity, specificity and accuracy for the detection of full-thickness tears compared with the detection of partial-thickness tears.

Limitations: Small sample size and retrospective.

Conflict Of Interest: None.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832332PMC
http://dx.doi.org/10.5144/0256-4947.2019.162DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
28
specificity accuracy
28
accuracy detection
16
tears compared
16
compared mri
16
accuracy shoulder
12
rotator cuff
12
detection full-thickness
12
accuracy
8
cuff pathologies
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!