A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low tube voltage increases the diagnostic performance of dual-energy computed tomography in patients with acute appendicitis. | LitMetric

Purpose: We aimed to assess the utility of dual-energy computed tomography (DECT) imaging in diagnosing acute appendicitis (AA) with density measurements of the appendix vermiformis.

Methods: A total of 210 consecutive patients presenting with acute abdominal pain were scanned using DECT between January and October 2016. Twenty-six patients had pathologically confirmed AA, while 30 had normal appendices. Appendiceal densities were measured in the true axial section of the appendix vermiformis at 80 kVp, 140 kVp, virtual noncontrast, iodine overlay, mixed, and monoenergetic (40, 50, 60, 70, 80, 90, 100 keV) images.

Results: Comparison of the appendix at different kVp and keV energy levels, virtual noncontrast, iodine overlay, and mixed images yielded significant differences between patients with appendicitis and those with a normal appendix (P < 0.001 for all). Receiver operating characteristic (ROC) curve analysis revealed that the 80 kVp image set yielded the best diagnostic performance among all image sets (area under the ROC curve [AUC], 0.996; P < 0.001), while 70 keV images yielded the highest diagnostic performance among the virtual monoenergetic image sets (AUC, 0.958; P < 0.001). Inter-rater agreement was good at 80 kVp images (intraclass correlation coefficient [ICC], 0.78, P < 0.001).

Conclusion: Evaluation of DECT image reconstructions suggested that low tube voltage with 80 kVp demonstrated accurate diagnostic performance for AA. This finding suggests that low kVp CT may be useful for diagnosing AA with reduced patient radiation exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6622438PMC
http://dx.doi.org/10.5152/dir.2019.18567DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
16
low tube
8
tube voltage
8
dual-energy computed
8
computed tomography
8
acute appendicitis
8
virtual noncontrast
8
noncontrast iodine
8
iodine overlay
8
overlay mixed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!