The relative motion between residual limb and prosthetic socket could be a relevant factor in quantifying socket fit. The measurement of these movements, particularly in dynamic gait situations, poses a challenging task. This paper presents the realization of a measurement concept based on multiple optical 2D-motion sensors. The performance of the system was evaluated on a test rig considering accuracy and precision as well as accomplished measurement frequency and reliability of the system. Additionally, results of a pilot study measuring the relative motion between residual limb and prosthetic socket at seven specific locations of one individual with transtibial amputation during straight level walking are presented. The sensor functionality of the array was confirmed and the test rig experiments were comparable to the previously tested functional model ( e r r rel = 0.52 ± 1.87 %). With a sampling frequency of 1.3 kHz to be distributed among the number of sensor units, the developed system is suitable for investigating the relative movement between residual limb and prosthetic socket in dynamic gait situations. Results of the pilot study show the majority of relative motion occurring during the second half of the gait cycle. The measured relative motions show the residual limb sinking deeper into the socket, extending in the Sagittal plane and rotating internally in the Transverse plane during stance phase. Data captured during swing phase indicate a lower limb extension in the Sagittal plane as well as an external rotation in the Transverse plane.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6631854 | PMC |
http://dx.doi.org/10.3390/s19122658 | DOI Listing |
Behav Pharmacol
January 2025
Department of Psychology, Massachusetts College of Liberal Arts, Massachusetts, USA.
In recent years, the recreational use of xylazine has increased dramatically in the USA. Although xylazine has been used as an anesthetic in veterinary medicine for decades, little is known about its behavioral effects. We took advantage of the planarian's innate negative phototaxis, the reliable movement from the light side to the dark side of a Petri dish, to explore the organism's suitability as an animal model for investigating the preclinical pharmacology of xylazine.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
Background: Timely recognition and addressing of concomitant cartilage damage at the time of meniscal allograft transplantation (MAT) is critical to warrant future success. However, there remains a scarcity of data comparing outcomes between MAT with and without cartilage procedures.
Purpose: To compare patient-reported outcomes and rates of complications, failures, reoperations, and graft survivorship after MAT with concomitant cartilage procedures (MAT/Cart) and MAT without (MAT/NoCart).
J Exp Orthop
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine The University of Tokyo Tokyo Japan.
Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).
Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.
Evolution
January 2025
Department of Geosciences, Pennsylvania State University, State College, PA, USA.
Seed size is a trait which determines survival rates for individual plants and can vary as a result of numerous trade-offs. In the palm family (Arecaceae) today, there is great variation in seed sizes. Past studies attempting to establish drivers for palm seed evolution have sometimes yielded contradictory findings in part because modern seed size variations are complicated by long-term legacies, including biogeographic differences across lineages.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, BC, Canada.
People with amblyopia show deficits in global motion perception, especially at slow speeds. These observers are also known to have unstable fixation when viewing stationary fixation targets, relative to healthy controls. It is possible that poor fixation stability during motion viewing interferes with the fidelity of the input to motion-sensitive neurons in visual cortex.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!