Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty.

Proc Inst Mech Eng H

1 Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Rostock, Germany.

Published: September 2019

Hip resurfacing arthroplasty may have distinct advantages for young and active patients, but large metal-on-metal bearings can be associated with increased wear, adverse tissue reactions and higher rate of implant loosening. Ceramic wear couples are a commonly used alternative to metals and therefore might be an alternative for hip resurfacing arthroplastys. The aim of this study was to evaluate the mechanical strength of femoral components made of an alumina-toughened zirconia composite by means of experimental testing and finite element analysis. For the mechanical characterization, ceramic femoral components (Ø: 48 mm) were tested under compression loading experimentally until fracture occurred or a maximum load of 85 kN was obtained. The femoral components were either loaded against a ceramic cup or a copper ring (outer diameter Ø: 7.0 mm). In addition, the complex geometry of the ceramic femoral component was simplified, and only the stem was loaded in a cantilever test until fracture. In addition, the fracture tests were numerically simulated to investigate the influence of additional loading conditions and geometric parameters, which were not experimentally tested. The experimental data were used for validation of the finite element analysis. None of the tested ceramic femoral components fractured at a compression load of 85 kN when they were loaded against a ceramic cup at an inclination angle of 45°. When the femoral components were loaded against a copper ring, the femoral components fractured at 29.9 kN at a testing angle of 45°. The fracture load was reduced when an angle of 30° and increased when an angle of 60° was simulated. Using an experimental cantilever test, the stem of the femoral component fractured at 1124.0 N. When the stem length was increased or the diameter was reduced by 10% in the finite element analysis, the fracture load was reduced. Decreasing the length or increasing the diameter led to an increase of the fracture load. The strongest influence was found for the reduction of the transition radius of the stem, with a decrease of the fracture load up to 27.2%. The analyzed femoral components made of alumina-toughened zirconia (ATZ) showed sufficient mechanical capability to withstand high loadings during unfavorable loading conditions. However, further biomechanical and tribological investigations are required before clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411919855296DOI Listing

Publication Analysis

Top Keywords

femoral components
32
ceramic femoral
16
fracture load
16
hip resurfacing
12
finite element
12
element analysis
12
femoral
10
characterization ceramic
8
components
8
resurfacing arthroplasty
8

Similar Publications

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA) has gained popularity for its potential ability to improve surgical precision and patient outcomes, despite concerns about its long learning curve and increased operative times. The aim of this study is to evaluate the learning curve of the ROSA® Knee System, the relationship between each phase of the learning curve and the accuracy of the robotic system in femoral component size and knee alignment prediction.

Methods: A single surgeon retrospective analysis of total operative time (TOT) and total robotic time was conducted.

View Article and Find Full Text PDF

This study introduces a novel anchor-type proximal femoral nail (AT-PFN) to improve the bone-fixation integrity over the standard screw-type nail (SST-PFN). Quasi-static incremental cyclic load test was performed to investigate load-displacement, cumulative deformation energy, time-strain, and backbone curves. The finite element analysis (FEA) was implemented to identify the stress and strain distributions.

View Article and Find Full Text PDF

[Treatment with TOPS for short femoral stump].

Oper Orthop Traumatol

January 2025

Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.

Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.

Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.

View Article and Find Full Text PDF

Dislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.

View Article and Find Full Text PDF

Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).

Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!