Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hypothesis: The purpose of the present study was described as the arthroscopically assisted procedure that uses a synthetic conoid ligament reconstruction using Zip Tight (Zimmer biomet, Warsaw, USA) and fracture-site fixation with K-wire. Our hypothesis was that this technique provided a satisfactory functional outcome with minimum complication.
Methods: 45 patients underwent operation to treat fractures of the distal clavicle between January 2014 and May 2017. The inclusion criteria were as follows: (1) there is an episode of trauma and it is the first fracture (2) distal clavicle fracture of Neer type IIb with dislocation in image findings. The exclusion criteria were as follows: (1) Neer type I, IIa and III of distal clavicle fracture (2) existing injury of rotator cuff, biceps tendon and labral during the arthroscopic procedure. Based on these criteria, 23 patients were included in this study. Clinical outcome assessments were performed using 1-year postoperative Quick DASH score, Constant-Murley score, ASES score. Radiological outcome consisted of antero-posterior and axillary radiographs.
Results: Mean clinical outcomes were as follows: Quick DASH score was 3.8 ± 2.8, ASES score was 92.3 ± 3.2 and Constant-Murley score was 94.1 ± 3.0. It was a highly satisfactory result in all of the score at 1-year follow-up. All patients had achieved radiographic union at a minimum 1-year follow-up. There were no cases of nonunion or osteolysis.
Conclusions: This study demonstrated that the arthroscopy-assisted treatment using Zip Tight and K-wire provided a satisfactory functional outcome with minimum complication with Neer type IIb fractures of the distal clavicle.
Level Of Evidence: IV, Case series, Treatment study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00402-019-03219-2 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!