Fully automated dried blood spot (DBS) extraction systems, online coupled to standard liquid chromatography-tandem mass spectrometry (LC-MS/MS) configurations, decrease the hands-on time associated with conventional DBS analysis, resulting in a higher sample throughput, making the technique more compatible with a high-capacity bioanalytical workflow. The aim of this study was to develop and validate an LC-MS/MS method, using a DBS-MS 500 autosampler, for the determination and quantification of four anti-epileptic drugs (carbamazepine, valproic acid, phenobarbital and phenytoin) and one active metabolite (carbamazepine-10,11-epoxide) in DBS samples. Method development included thorough optimization of the fully automated extraction procedure (i.e. extraction solvent, extraction (loop) volume, internal standard application, internal standard drying time, etc.). The method was fully validated based on international guidelines. Accuracy (%bias), as well as precision (%RSD) (with a single exception) were below 13%. Neither carry-over nor unacceptable interferences were observed. All compounds were stable in DBS for at least 1 month when stored at room temperature, 4 °C and -20 °C and for at least 4 days when stored at 60 °C. Internal standard-corrected matrix effects were below 8%, with %RSDs below 9.1%. Reproducible relative recovery values (around 60% for all analytes) were obtained and the effect of the hematocrit on the relative recovery was overall limited. Successful application on capillary patient samples originating from developing countries demonstrated the applicability of the developed procedure in a remote setting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2019.06.022 | DOI Listing |
Anal Chem
January 2025
Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, U.K.
Total free thiols are an important marker of the whole-body redox state, which has been shown to be associated with clinical outcome in health and disease. Recent investigations have suggested that increased insight may be gained by monitoring alterations of redox state in response to exercise and hypoxia and to monitor redox trajectories in disease settings. However, conducting such studies is challenging due to the requirement for repeated venous blood sampling and intensive lab work.
View Article and Find Full Text PDFHistol Histopathol
January 2025
University of Arizona, Phoenix, AZ, USA.
In larger, translational animal models, manual measurements of longitudinal bone growth using fluorochrome labels is tedious and may be prone to less rigor due to variations in reader experience, sampling differences, and photobleaching that limits the repeatability of measurements. This study assesses the reliability of three different digital methods to assist in measurement of distance between pulsed fluorochrome labels. Forty-five tibial physes from skeletally immature New Zealand White rabbits were pulsed with fluorochrome labels and measured using Fully Manual Technique (FMT), Manual Digital Measurement (MDM), Computer Assisted Image Processing (AIP), and Fully Automated Measurement (FAM).
View Article and Find Full Text PDFFront Neurosci
January 2025
Neurology Associate P.C., Lincoln, NE, United States.
Introduction: As a hallmark feature of amyotrophic lateral sclerosis (ALS), bulbar involvement significantly impacts psychosocial, emotional, and physical health. A validated objective marker is however lacking to characterize and phenotype bulbar involvement, positing a major barrier to early detection, progress monitoring, and tailored care. This study aimed to bridge this gap by constructing a multiplex functional mandibular muscle network to provide a novel objective measurement tool of bulbar involvement.
View Article and Find Full Text PDFJ Alzheimers Dis
January 2025
Aging Brain and Memory Clinic, Department of Neuroscience "Rita Levi-Montalcini", University of Torino, Torino, Italy.
This study evaluated the diagnostic performance of plasma biomarkers for Alzheimer's disease (AD) using an automated platform. In a cohort of 74 consecutive patients, plasma p-Tau181 levels were significantly higher in AD compared to non-AD groups and showed correlation with cerebrospinal fluid biomarkers. Plasma p-Tau181 demonstrated high diagnostic accuracy for AD, with an area under the curve of 0.
View Article and Find Full Text PDFAm J Hematol
January 2025
Clinic III (Hematology, Oncology and Palliative Medicine), Special Hematology Laboratory, Rostock University Medical School, Rostock, Germany.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!