Novel Electrochemical Flow Sensor Based on Sensing the Convective-Diffusive Ionic Concentration Layer.

ACS Sens

Faculty of Mechanical Engineering, Micro- and Nanofluidics Laboratory , Technion - Israel Institute of Technology, Technion City 3200000 , Israel.

Published: July 2019

Presented is a novel flow sensor based on electrochemical sensing of the ionic concentration-polarization (CP) layer developed within a microchannel-ion permselective membrane device. To demonstrate the working principle of the electrochemical flow sensor, the effect of advection on the transient and steady-state ionic concentration-polarization (CP) phenomenon in microchannel-Nafion membrane systems is studied. In particular, we focused on the local impedance, measured using an array of electrode pairs embedded at the bottom of the microchannel, as well as the total current across the permselective medium, as two approaches for estimating the flow. We examined both a stepwise application of CP under steady-state flow and a stepwise application of flow under steady-state CP.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.9b00431DOI Listing

Publication Analysis

Top Keywords

flow sensor
12
electrochemical flow
8
sensor based
8
ionic concentration-polarization
8
stepwise application
8
flow
6
novel electrochemical
4
based sensing
4
sensing convective-diffusive
4
convective-diffusive ionic
4

Similar Publications

synthesis of a UIO-66-NH@TiC composite for advanced electrochemical detection of acetaminophen.

Nanoscale

January 2025

Hubei Key Laboratory of Material Chemistry and Service Failure, Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Engineering Research Center for Biomaterials and Medical Protective Materials, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Rd, Wuhan, China.

Acetaminophen (AP) is a widely used analgesic and antipyretic drug, but its excessive use poses health risks and contributes to environmental contamination. In response to the need for rapid, accurate, and cost-effective detection methods, we developed a highly sensitive and selective electrochemical sensor for AP. The sensor was based on a composite of UIO-66-NH (UN) and an MXene (TiC).

View Article and Find Full Text PDF

The big potassium (BK) channels remain open with a small limiting probability of ∼ 10 at minimal Ca and negative voltages < -100 mV. The molecular origin and functional significance of such "intrinsic opening" are not understood. Here we combine atomistic simulations and electrophysiological experiments to show that the intrinsic opening of BK channels is an inherent property of the vapor barrier, generated by hydrophobic dewetting of the BK inner pore in the deactivated state.

View Article and Find Full Text PDF

Vertical flow immunoassay for multiplex mycotoxins based on photonic nitrocellulose and SERS nanotags.

Food Chem X

January 2025

State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.

Here, we report a SERS based VFA using PNC as a sensing substrate for highly sensitive multiplex mycotoxins detection. The PNC was fabricated by filtration-based self-assembled monodisperse SiO NPs on a filter membrane as a template, and the obtained PNC had an ordered complementary inverse opal structure. In parallel, three kinds of Raman dyes encoding Au@Ag, Au@Ag and Au@Ag SERS nanotags were synthesized for the detection of OTA, AFB1 and ZON.

View Article and Find Full Text PDF

Microplastics (MP) are known to be ubiquitous. The pathways and fate of these contaminants in the marine environment are receiving increasing attention, but still knowledge gaps exist. In particular, the link between mass-based MP quantification and oceanographic parameters is often lacking.

View Article and Find Full Text PDF

Electrochemical impedance spectroscopy has great potential for laboratory blood tests. The overall aim of this study is to develop a microfluidic sensor for determining the physical properties and hematological parameters of blood based on its dielectric spectra. Impedance was measured in flowing blood to prevent aggregation and sedimentation at frequencies between 40 Hz and 110 MHz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!