A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Target capturing performance of microfluidic channel surface immobilized aptamers: the effects of spacer lengths. | LitMetric

Target capturing performance of microfluidic channel surface immobilized aptamers: the effects of spacer lengths.

Biomed Microdevices

Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5, Canada.

Published: June 2019

Aptamers have been widely used to recognize and capture their targets in sensitive detection applications, such as in detections of circulating tumor cells. In this study, we investigate the effects of different lengths of oligo-T spacers on surface tethered sgc8 aptamers and their target capturing performances. To achieve this, sgc8 aptamers were immobilized onto microfluidic channel surfaces via oligo-T spacers of different lengths, and the target capturing performances of these immobilized aptamers were studied using CCRF-CEM cells. We demonstrate that the capturing performances of the immobilized aptamers were significantly affected by steric hindrance. Our results also show that aptamers immobilized on surfaces via spacers of ten Ts demonstrated the best cell capturing performances; aptamers with either too short or too long oligo-T spacers showed reduced cell capturing performances. Therefore it can be concluded that spacer optimizations are critically important for surface tethered aptamers that are commonly used in microfluidic devices for sensitive target sensing and detections.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10544-019-0403-zDOI Listing

Publication Analysis

Top Keywords

capturing performances
20
target capturing
12
immobilized aptamers
12
oligo-t spacers
12
aptamers
9
microfluidic channel
8
surface tethered
8
sgc8 aptamers
8
aptamers immobilized
8
performances immobilized
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!